9x5xorb) Be capable of generating a secondary signal identifiable at the ARC asa mis-operation signal (see Command 36 Alarm Abort).PD 6662 / prEN 50131-1: 2004 ComplianceEN 50131-1: 2004, Alarm systems – Intrusions and Hold-up Systems – Part1: System Requirements, requires that an alarm system does not display anydetailed information until a user enters a valid access code or presents avalid proximity tag. The system should display an alert to inform users thatthere is information to view. There are four grades of system:Grade 1Grade 2Grade 3Grade 4The 9651 control unit can be configured to comply with thisgrade.The 9751/2 control units can be configured to comply withthis grade.The 9853 control unit can be configured to comply with thisgrade.9x5x control units are not designed to comply with thisgrade.Note: 9x5x control units do not reflect variations set out in EN 50131-1:1997. The 9651 unit is not covered by this Programming Guide.Programming for ComplianceUse the following setting to ensure compliance with PD 6662 / prEN 50131-1: 2004.N/A = Not applicableCommand Grade 1/2 Grade 3 Notes21 any N/A 9751/2any 2/3 985326 0 027 0 028 1 129 1 137 any 141 ≤ 10 min ≤ 10 min42 ≤ 15 min ≤ 15 min66 of 76 Issue 1