11.07.2015 Views

Cooper TP Workshop Manual_Scant:Layout 1 7/8 ... - Cooper Security

Cooper TP Workshop Manual_Scant:Layout 1 7/8 ... - Cooper Security

Cooper TP Workshop Manual_Scant:Layout 1 7/8 ... - Cooper Security

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

95EN, 85EN, 65ENThe Engineer Menu00: Go to User Menus1= Omit Zones 5= Engineer Tools2= Omit 24Hr Grps 6= Time and Date3= System Options 7= Custom Text4= Test Options 9= Log01: Display Location Text1= Panel 2= Keypad10: Program Zones11: Edit ZonesZone type:0= Not Used Shunt Key1= Normal Alm Tamper2= 24 Hour Perimeter3= PA Silent Lock Set4= PA Audible PSU Battery5= Fire PSU Fuse6= Technical PSU Power7= Final Exit Masking8= Exit Term Occupancy9= Entry <strong>Security</strong>KeyswitchAttributes:1= Access 9= Chime Tone 22= Double Knock Chime Tone 33= Soak Test Inverted4= Omittable Shuntable5= Reset Beam Pair6= Masking Monitored7= Entry Non Latching8= Chime Tone 1 SupervisionActivity12: Zone Resistances1= 4K7/2K2 3= 4K7/4K72= 1K0/1K0 4= 2K2/2K213: Alter Shunt Groups14: TelecommandsTelecommand Type:1= Local 3= Unused2= GlobalButtons:1= Button 1 4= Button 42= Button 2 5= PA (Btn 1+4)3= Button 3Telecommand Name20: Partitions21: View Prtns22: Exit Modes1= Final Exit 5= Deferred Set2= Exit Terminate 6= Lock Set3= Timed Exit 7= Silent Set4= Instant Set23: Partition Timers1= Exit 3= Bell Delay2= Entry 4= Bell Duration24: Alarm Responses1= Full 3= Internal2= Local25: Partition Resets & Options1= Conf Reset 6= F/E=Norm.Alm2= Unconf Reset 7= Entry= F/E3= Tamper Reset 8= Full Set Link4= Remote Reset 9= ENT Key Sets5= Foyer Mode 10= Entry Unset26: Equipment to Partitions30: Edit Outputs31: Panel OutputsOutput follows:1= System 3= Zone2= Ptns 4= UserIf following the system:000= Bell (SAB) 052= Relearn Required001= System Strobe 053= Always On002= Switch 12 Volts 054= Always Off003= Detector Reset 055= Battery Test On004= Walk Test 056= Battery Fault005= Burg 057= PSU - Battery006= Panic Alarm (PA) 058= PSU - Fuse007= Fire Alarm 059= PSU - Power008= System Set 060= General Fault009= System Full Set 061= Mask Tamper010= System Open 062= Mask Fault011= Confirmed 063= Mask Alarm012= Courtesy Light 064= 4k4 Fault Output013= Engineer On Site 065= Pending014= Active Omit 066= Always Off015= Zones Omitted 067= Ext. Line Fault016= 24 Hour Omitted 068= ATS Test017= 24 Hour Alarm 069= Always Off018= Zones Shunted 070= Auxiliary Fuse019= Technical 071= Bell Fuse020= PSTN Line Fault 072= Network 1 Fuse021= Mains Power Off 073= Network 2 Fuse022= Access Code 074-079= Always Off023= Soak Test Fail 080=Rem Batt Fault45 of 72

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!