660/9606601. Remove the backing from the self adhesive pads on the back of thecommunicator. Locate the communicator in a convenient position withinthe control panel. Press firmly to fix.2. Connect the 12V +ve and -ve supply from the Aux DC output on thecontrol panel (see diagram).Figure 3. 660 Connection3. Connect the inputs required. For guidance: ST1 - Fire, ST2 - PA(Panic), ST3 - Burg (intruder), ST4 - Spare.Note: Connect input triggers as closed circuit (removed in alarm) if the communicatoris housed in a separate enclosure from the control panel.4. Set the input mode selector DIP switch to positive applied or positiveremoved as required.9601. Locate the communicator on the pins (see specific control panel installationinstructions for correct communicator location).Figure 4. 960 Connection3. Connect any external trigger device required to ST 8 (Spare) - seeFigure 4.4 of 16 496354 Issue 1