95EN, 85EN, 65ENDefault ValuesSettings Defaulted Grade2(Grade 3)Default ValueUser 05-1 Engineer Access Infinite(see note 1)User 08 User CodesUser 01 code 1234 (123400)User 01 partitionsAllUser name User 001User 02 and beyondNot usedEng 10 to 12 ZonesZone type (all zones)Not Used(see note 2)Zone descriptionZone xResistance4K7/2K2Eng 13 Shunt GroupsZones assignedNoneEng 14 TelecommandsGlobal Users No Text Name, All Buttons Ptn 1Eng 22 Setting ModesAll PartitionsTimed Set(see note 3)Eng 23 Prtn Tmrs01 Exit 030 Seconds02 Entry 015 Seconds03 Bell Delay 000 Minutes04 Bell Duration 015 MinutesEng 24 Setting Partition Alarm ResponseFullEng 25 Ptn Rsts & Opts01 Conf Reset Partitions: 102 Unconf Reset Partitions: None03 Tamper Reset Partitions: All04 Remote Reset Partitions: None05 Foyer Mode Partitions: None06 F/E=Norm.Alm None07 Entry=F/E None08 Full Set Link None09 ENT Key Sets Partition 110 Entry Unset AllEng 26 Equip To PrtnsAll devicesAll partitionsEng 30 Outputs01 Panel Output 1 Walk Test02 Panel Output 2 Courtesy Light03 Panel Output 3 Set Pulse04 Panel Output 4 (not 65) Detector Reset05 Panel Output 5 (not 65/85) Unset PulseEng 32 Digi Hardwired01 Digi H/Wired 01 Fire Alarm02 Digi H/Wired 02 PA03 Digi H/Wired 03 Alarm04 Digi H/Wired 04 System Set05 Digi H/Wired 05 Active Omit06 Digi H/Wired 06 Abort07 Digi H/Wired 07 Confirmed08 Digi H/Wired 08 Tamper Alarm09 Digi H/Wired 09 (not 65) Mains Power Off10 Digi H/Wired 10 (not 65) General Fault11 Digi H/Wired 11 (not 65) RF Low Battery12 Digi H/Wired 12 (not 65) Supervision13 Digi H/Wired 13 (not 65) Jamming14 Digi H/Wired 14 (not 65) ATS Test15 Digi H/Wired 15 (not 65) Always OffSettings Defaulted Grade2(Grade 3)Default Value16 Digi H/Wired 16 (not 65) Always OffEng 33 Digi On Board01 Digi On Board 01 Fire Alarm02 Digi On Board 02 PA03 Digi On Board 03 Alarm04 Digi On Board 04 System Set05 Digi On Board 05 Active Omit06 Digi On Board 06 Abort07 Digi On Board 07 Confirmed08 Digi On Board 08 Tamper Alarm09 Digi On Board 09 Mains Power Off10 Digi On Board 10 General Fault11 Digi On Board 11 RF Low Battery12 Digi On Board 12 Supervision13 Digi On Board 13 Jamming14 Digi On Board 14 Always Off15 Digi On Board 15 Always Off16 Digi On Board 16 Always OffEng 34 All Equipment O/Ps PendingEng 35 All Output Module O/Ps Always Off (not 65EN)Eng 36 Time Switches01 On times 1, 2 & 3 00:0002 Off times 1, 2 & 3 00:0003 Timers operate on No daysEng 41 User Codes01 Engineer code 7890 (789000)02 Engineer Name EngineerEng 42 Time and Date01 Set Time 00:0002 Set Date As per s/w dateEng 44 System Timers01 Confirmation 030 Minutes02 Sys Bell Dly 000 Minutes03 Sys Bell Dur 015 Minutes04 Anti Mask 005 Seconds05 Line Fault 030 Seconds06 AC Off Delay 030 Seconds07 Soak Test 014 Days08 Exit Settle 005 Seconds09 2nd Entry Dly 000 Seconds10 Double Knock 010 Seconds11 Abort Period 060 Seconds12 Abort Delay 120 Seconds13 Courtesy Time 120 Seconds14 Menu Time-Out 180 Minutes15 Beam Pair 010 Seconds16 Defer Setting 010 Minutes17 Service Time 000 Days18 Select Menu 030 Seconds19 Keys Till Tamp 041 Counts20 No. of Rearms 000 Counts21 Remote Resets 032 Counts22 Double Knocks 002 Counts23 Tst Call Strt 000 Hours24 Tst Call Int 24 Hours25 Reset Alg 004 (021)(see note 4)26 Payment Time 000 Days27 Sup Warning 16 Minutes28 Sup Failure 120 Minutes48 of 72

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!