9500Initial Start UpProgrammingCheck that all LIM box tampers are closed. Make sure that the Bell andStrobe is not connected to the main 9500 PCB. Link out any circuits that arennot used.When powering up the panel for the first time:1. Close the control panel lid and connect the mains supply.The display shows:12:00 16 OCT 90Alternating with: 12:00 16 OCT 90Status : Alarm2. Key in 4567 + Enter.The display shows:3. Press No.The display shows:Displaycustomer log?12:00 16 OCT 90Alternating with: 16 OCT 12:00:00CALL ENGINEER4. Key in 7890 + Enter.The display shows: Ver 4.2014 FEB 1991Followed by:Do you wantengineer reset?Note: Whenever you enter engineer mode, the software version number and its datewill be displayed. Make a note of this number, as it will be useful when contactingthe <strong>Scant</strong>ronic Product Support Department with any queries.5. Press No.The display shows:6. Press No.The display shows:7. Press No.The display shows:8. Open the control panel lid.Do you wanttest functions?Do you wantreports?Do you want toprogram the system?10 of 22 496332 Issue 1