TABLE V.5PLANT-PARAMETERS KEYWORDSCh i llersChiller control schemeChiller water temperature, mid-throttling rangeChiller temperature controller throttling rangeCooling tower water flow/Compression chiller capacityMinimum entering air temp., air-cooled condenserDouble-bundled Chiller to Tower WaterFull-load heat input ratio, I-stage absorption chillerFull-load heat input ratio, 2-stage absorption chillerFull-load heat input ratio, solar-driver absorptionch illerCooling tower water flow/Absorption chiller capacityFan electric power/Hermetic centrifugal chiller capacityCondenser type, hermetic centrifugal chillerMaximum PLR for hot gas bypass, hermetic centrifugalchillerFan electric power/Hermetic reciprocating chillerCondenser type, hermetic reciprocating chillerMaximum PLR for hot gas bypass, hermetic reciprocatingch illerFan electric power/Open centrifugal chiller capacityCondenser type, open centrifugal chillerCompressor motor efficiency, open centrifugal chillerMaximum PLR for hot gas bypass, open centrifugal chillerFan electric power /Open reciprocating chiller capacityCondenser type, open reciprocating chillerCompressor motor efficiency, open reciprocating chillerMaximum PLR for hot gas bypass, open reciprocating chillerCapacity correction factor, double-bundle chiller,w/heat recoveryEntering condenser temperature at design w/o heat recovery,double-bundle chillerLeaving condenser temperature w/heat recovery, doublebundlechillerPower correction factor w/heat recovery, double-bundlech i 11 erRecoverable heat/Total heat rejection at full load,w/heat recovery, double-bundle chillerMinimum PLR to operate w/o hot gas bypass, w/o heatrecovery, double-bundle chillerMinimum PLR to operate w/o hot gas bypass, w/heat recovery,double-bundle chillerCHILLER-CONTROLCHILL-WTR-TCHILL-WTR-THROTTLECOMP-TO-TWR-WTRMIN-COND-AIR-TDBUN-TO-TWR-WTRABSORI-HIRABSOR2-HIRABSORS-HIRABSOR-TO-TWR-WTRHERM-CENT-COND-PWRHERM-CENT-COND-TYPEHERM-CENT-UNL-RATHERM-REC-COND-PWRHERM-REC-COND-TYPEHERM-REC-UNL-RATOPEN-CENT-COND-PWROPEN-CENT-COND-TYPEOPEN-CENT-MOTOR-EFFOPEN-CENT-UNL-RATOPEN-REC-COND-PWROPEN-REC-COND-TYPEOPEN-REC-MOTOR-EFFOPEN-REC-UNL-RATDBUN-CAP-COR-RECDBUN-COND-T-ENTDBUN-COND-T-RECDBUN-EIR-COR-RECDBUN-HT-REC-RATDBUN-UNL-RAT-DESDBUN-UNL-RAT-RECCooling TowerMinimum temperature, leaving tower cooling waterExponent used to modify rating factor for off-design airflowsMaximum water flow per cell/Design flow per cellWet-bulb temperatureMIN-TWR-WTR-TRFACT-CFM-EXPONENTTWR-CELL-MAX-GPMTWR-DESIGN-WETBULBV.23 (Revised 5/81)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!