12.07.2015 Views

DOE-2 Reference Manual Version 2.1 - DOE2.com

DOE-2 Reference Manual Version 2.1 - DOE2.com

DOE-2 Reference Manual Version 2.1 - DOE2.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TABLE V.5 (cant)Tower fan: one-speed or two-speedFan-low-speed airflow rate/fan-high-speed airflow rateFan power at low speed/Fan power at high speedNatural convection airflow rate/design airflow rateCirculation pump efficiencyTower pump motor efficiencyPressure head in tower water circulation loopExiting water temperature floating or fixedExiting water temperature when set to "fixed"Effective throttling range about water set pointDirect cooling control schemeMaximum outdoor dry-bulb temperature for whichdirect cooling is allowedSchedule for direct cooling availabilityMaximum chilled water temperature for whichdirect cooling is allowedDirect cooling auxiliary equipment electric demandBoilersBoiler blowdown flow rate as fraction of steam turbinesteam lossesBoiler control: demand-only or standbyFuel used for boilerFraction of total capacity of electric hot-water boilerlost through skin or leads, while operatingFraction of total capacity of electric steam boiler lostthrough skin or leads, while operatingHeat input ratio, hot water boilerMakeup water temperatureEffectiveness of blowdown heat recovery, steam boilerHeat input ratio, steam boilerDomestic Hot-Water HeatersHeat input ratio, domestic hot-water heaterFuel used by domestic hot-water heaterFraction of total capacity of electric hot-water heaterlost through skin or leads, while operatingFurnacesHeat input ratio for the furnaceFuel used by the furnaceFuel consumption of a pilot light when a gasfurnace is not firingGeneratorsFuel used by diesel generatorMaximum exhaust flow/electric output, diesel generatorFuel used by gas turbineMaximum exhaust flow/electric output, gas turbineExhaust steam pressure, steam turbineEntering steam pressure, steam turbineRpm of steam turbine at nominal capacityV.24TWR-FAN-CONTROLTWR-FAN-LOW-CFMTWR-FAN-LOW-ELECTWR-FAN-OFF-CFMTWR-IMPELLER-EFFTWR-MOTOR-EFFTWR-PUMP-HEADTWR-TEMP-CONTROLTWR-WTR-SET-POINTTWR-WTR-THROTTLEDIRECT-COOL-MODEDC-MAX-TDIRECT-COOL-SCHDC-CHILL-WTR-TDIRECT-COOL-KWBOILER-BLOW-RATBOILER-CONTROLBOILER-FUELE-HW-BOILER-LOSSE-STM-BOILER-LOSSHW-BOILER-HIRMAKEUP-WTR-TRECVR-HEAT/BLOWSTM-BOILER-HIRDHW-HIRDWH-HEATER-FUELELEC-DHW-LOSSFURNACE-HIRFURNACE-FUELFURNACE-AUXDIESEL-FUELMAX-DIESEL-EXHGTURB-FUELMAX-GTURB-EXHSTURB-EXH-PRESSTURB-PRESSTURB-SPEED(Revised 5/81)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!