DOE-2 Reference Manual Version 2.1 - DOE2.com

DOE-2 Reference Manual Version 2.1 - DOE2.com

DOE-2 Reference Manual Version 2.1 - DOE2.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OPEN-CENT-EIR-FPLR is the same as HERM-CENT-EIR-FPLR, but for an opencentrifugal compression chiller.OPEN-CENT-EIR-FTOPEN-REC-CAP-FTOPEN-REC-EIR-FPLROPEN-REC-EIR-FTDouble-Bundle ChillersDBUN-CAP-FTDBUN-CAP-FTRISEDBUN-EIR-FPLRDBUN-EIR-FTDBUN-EIR-FTRISEis the same as HERM-CENT-EIR-FT, but for an opencentrifugal compression chiller.is the same as HERM-CENT-CAP-FT, but for an openreciprocating compression chiller.is the same as HERM-CENT-EIR-FPLR, but for an openreciprocating compression chiller.is the same as HERM-REC-EIR-FT, but for an openreciprocating compression chiller.accepts the U-name of a CURVE-FIT instruction that definesa bi-linear or bi-quadratic equation. The equation will beused to describe the capacity of a double-bundle chiller asa function of exit water temperature and entering condenserwater temperature. This function should be normalized sothat f(CHILL-WTR-T, DBUN-COND-T-ENT) = 1.0. When in heatrecovery mode, DBUN-COND-T-ENT is used in place of the actualentering condenser water temperature to eliminate theeffect of the entering water temperature on the capacity.accepts the U-name of a CURVE-FIT instruction that definesa linear or quadratic equation. That equation definesdouble-bundle chiller capacity correction factor as afunction of the difference between the exiting condenserwater temperatures in the heat recovery and non-heatrecoverymodes. It is normalized so that if 6T = 0, it = 1.accepts the U-name of a CURVE-FIT instruction that definesa linear or quadratic equation. The equation will describethe electric-input ratio of a double-bundle chiller as afunction of part-load ratio.accepts the U-name of a CURVE-FIT instruction that definesa bi-linear or bi-quadratic equation. The equation will beused to describe the electric input ratio adjustment factorof a double-bundle chiller as a function of exit water temperatureand entering condenser water temperature. Thisfunction should be normalized so that f(CHILL-WTR-T, DBUN­COND-T-ENTJ = 1.0. When in the heat-recovery mode, DBUN­COND-T-ENT is used to eliminate the effect of the enteringcondenser water temperature on the electric input ratio.accepts the U-name of a CURVE-FIT instruction that definesa linear or quadratic equation. The equation will expresselectric input ratio as a function of "TRISE" (seeDBUN-CAP-FTRISE).V.42 (Revised 5/81)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!