REPORT PS-G - ELECTRICAL LOADS SCATTER PLOTIn this scatter plot the ordinate, shown in the left most column, is theelectrical demand divided into 13 blocks ranging from zero to just above thepeak electrical demand. The abscissa shown at the top is the hour of theday. Entered in each cell of the plot is the number of days during the yearfor which the electrical demand was less than the ordinate shown but largerthan the next lower ordinate at that hour of the day. Thus there were 358days of the year when the electrical demand between midnight and 1:00 a.m.was between 3 and 0 kWh. Similarly there were 122 days in the year when theelectrical demand was between 18 and 15 kWh in the 9th hour between 8:00a.m. and 9:00 a.m.The right most column is the sum of the entries in each row and showsthe relative frequency of the electrical demand throughout the year.The bottom row is the frequency of the electrical demand for each hourof the average day.The chart at the bottom i',s a breakdown of the peak electrical demandinto the contributing components. The SYSTEMS LOAD includes the lightingand equipment electrical loads from LOADS as well as that from system fans.VIL10?