12.07.2015 Views

DOE-2 Reference Manual Version 2.1 - DOE2.com

DOE-2 Reference Manual Version 2.1 - DOE2.com

DOE-2 Reference Manual Version 2.1 - DOE2.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ABSORS-CAP-FTABSORS-CAP-FTSABSORS-HIR-FPLRABSORS-HIR-FTABSORS-HIR-FTSCompression ChillersHERM-CENT-CAP-FTis like ABSOR1-CAP-FT for a solar-driven absorption chiller.accepts as input the U-name of a CURVE-FIT instruction thatdefines a linear or quadratic equation. That equation willbe used to express the capacity correction factor of asolar-driven absorption chiller as a function of thetemperature of the hot water from the solar equipment.is like ABSOR1-HIR-FPLR for a absorption chiller.is like ABSOR1-HIR-FT for a absorption chiller.accepts the U-name of a CURVE-FIT instruction that definesa linear or quadratic equation. That equation will be usedto express the heat input ratio correction factor of asolar-driven absorption chiller as a function of thetemperature of the hot water from the solar equipment.accepts the U-name of a CURVE-FIT instruction that definesa bi-linear or bi-quadratic equation. That equation willbe used to express the correction factor for the capacityof a hermetic centrifugal compression chiller as a functionof the exiting chilled water temperature and entering watertemperature (see -CAP-FT). It is normalized to 1.0 atdesign conditions.HERM-CENT-EIR-FPLR accepts the U-name of a CURVE-FIT instruction that definesa linear or quadratic equation. That equation will be usedto express the electric input ratio correction factor of ahermetic centrifugal compression chiller as a function ofits part-load ratio (see -EIR-FPLR).HERM-CENT-EIR-FTHERM-REC-CAP-FTHERM-REC-EIR-FPLRHERM-REC-EIR-FTOPEN-CENT-CAP-FTaccepts the U-name of a CURVE-FIT instruction that definesa bi-linear or bi-quadratic equation. That equation willbe used to express the electric input ratio correctionfactor of a hermetic centrifugal compression chiller as afunction of exiting chilled water temperature and enteringwater temperature (see -EIR-FT).is the same as HERM-CENT-CAP-FT, but for a hermeticreciprocating compression chiller.is the same as HERM-CENT-EIR-FPLR, but for a hermeticreciprocating compression chiller.is the same as HERM-CENT-EIR-FT, but for a hermeticreciprocating compression chiller.is the same as HERM-CENT-CAP-FT, but for an opencentrifugal compression chiller.V.41 (Revised 5/81)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!