Setting the No. 3 Display Section 3-11<br />

3-11 Setting the No. 3 Display<br />

3-11-1 PV/SP Display Selection<br />

MV Display for<br />

Heating and Cooling<br />

Control<br />

82<br />

This section describes how to set the No. 3 Display (<strong>E5AN</strong>/EN-H). The bank<br />

No., MV, or soak time remain can be displayed on the No. 3 display.<br />

The following table shows the set values and display contents for the PV/SP<br />

Display selection.<br />

Set value Display contents<br />

0 Only PV/SP is displayed (with no No. 3 display.)<br />

1 PV/SP/Bank No. and PV/SP/MV are displayed in order. (See note 2.)<br />

2 PV/SP/MV and PV/SP/Bank No. are displayed in order. (See note 2.)<br />

3 Only PV/SP/Bank No. is displayed.<br />

4 Only PV/SP/MV is displayed. (See note 2.)<br />

5 PV/SP/Bank No. and PV/SP/Soak time remain are displayed in order.<br />

6 PV/SP/MV and PV/SP/Soak time remain are displayed in order. (See<br />

note 2.)<br />

7 Only PV/SP/Soak time remain is displayed.<br />

Note (1) The default setting is 4.<br />

(2) For details on setting the MV for heating and cooling control, refer to MV<br />

Display for Heating and Cooling Control below. The MV for position-proportional<br />

models becomes the value for opening the valve.<br />

When 1, 2, 5, or 6 is selected, press the M Key to display the next value set<br />

for the PV/SP display (display 2).<br />

Example: When the PV/SP Display Screen Parameter Is Set to 2<br />

Operation Level<br />

PV/SP (Display 1)<br />

25.0<br />

100.0<br />

50.0<br />

Press the<br />

M key<br />

C C<br />

PV/SP (Display 2)<br />

25.0<br />

100.0<br />

b.0<br />

PV/SP/MV PV/SP/Bank No.<br />

Select either the manipulated variable (heating) or manipulated variable (cooling)<br />

as the MV to be displayed for PV/SP/MV during heating and cooling control.<br />

This parameter is displayed only when heating/cooling control is being<br />

performed and PV/SP/MV is selected in the PV/SP Display Screen parameter<br />

or a Monitor/Setting Item Display parameter. This setting can be made for<br />

standard models only.<br />

Parameter name Set value Symbol Display contents<br />

MV Display Selection O o Manipulated variable<br />

(heating)<br />

C-O c-o Manipulated variable<br />

(cooling)