Changed<br />

parameter<br />

Related initialized parameters<br />

Related parameter initialization<br />

execution condition<br />

Bank 1 to 7 SP --- --- --- --- --- ---<br />

Bank 0 to 7 Wait Band --- --- --- --- --- ---<br />

--- --- --- --- --- ---<br />

PID 1 to 8 Proportional Band<br />

(See note 16.)<br />

PID 1 to 8 Integral Time (See note 16.) --- ● (See note 17.) --- --- --- ---<br />

PID 1 to 8 Derivative Time<br />

(See note 16.)<br />

PID 1 to 8 MV Upper Limit,<br />

PID 1 to 8 MV Lower Limit<br />

PID 1 to 8 Automatic Selection Range<br />

Upper Limit<br />

Transfer Output<br />

Type<br />

Floating/Closed Bank Numbers<br />

Used<br />

--- Models with<br />

positionproportional<br />

control and FB<br />

input<br />

PID Set<br />

Automatic<br />

Selection Data<br />

Direct Setting of<br />

Position<br />

Proportional MV<br />

--- Models with<br />

positionproportional<br />

control and FB<br />

input, close<br />

control<br />

--- --- --- --- --- ---<br />

--- --- --- --- --- ---<br />

--- --- --- ● (See note 14.) --- ---<br />

Appendix<br />

Password to<br />

Move to Protect<br />

Level<br />

Note (1) Initialized to input setting range upper and lower limits, or scaling upper and lower limits.<br />

(2) Initialized to SP upper and lower limits.<br />

(3) Clamped by SP upper and lower limits.<br />

(4) Initialized only when the input type is changed to analog input when RT turns ON. The defaults are<br />

as follows: RT: OFF<br />

(5) Initialization is performed as shown below according to the transfer output type setting. The initialization<br />

differs depending on the changed parameter and the output type setting.<br />

SP: SP upper and lower limits<br />

Ramp SP: SP upper and lower limits<br />

PV: Input setting range upper and lower limits or scaling upper and lower limits<br />

MV (Heating): 100.0/0.0<br />

MV (Cooling): 100.0/0.0<br />

Valve Opening: 100.0/0.0<br />

(5.1) Initialized only when the transfer output type is set to SP, Ramp SP, or PV.<br />

(5.2) Initialized only when the transfer output type is set to MV (Heating) or MV (Cooling).<br />

(5.3) Initialized to the above default values regardless of the settings for changing the transfer output<br />

type.<br />

(6) Initialized as follows according to the Standard or Heating/Cooling parameter setting.<br />

MV Upper Limit: 105.0<br />

MV Lower Limit: Standard −5.0, heating/cooling −105.0<br />

(7) For standard models, initialized to control output (cooling) for heating/cooling control, according to<br />

the following. (The defaults for standard control and for models with position-propotional control are<br />

the defaults in the parameter list.)<br />

With control output 2: The Control Output 2 Assignment parameter is initialized to control output<br />

(cooling).<br />

Without control output 2 and E5CN-H: The Auxiliary Output 2 Assignment parameter is initialized to<br />

control output (cooling).<br />

(8) When the program pattern is OFF, the Auxiliary Output 1 Assignment parameter is initialized to<br />

alarm output 1. When the program pattern is not OFF, the Auxiliary Output 1 Assignment parameter<br />

is initialized to program end output.<br />

(9) When the program pattern is changed to OFF, if the Program Start parameter is assigned it is initialized<br />

to “not assigned.”<br />

(10) If the password is changed, it will be initialized to the new password.<br />

---<br />

333