Auxiliary Output 1<br />

Assignment<br />

326<br />

sub1 NONE: No assignment<br />

O: Control output (heating)<br />

C-O: Control output (cooling)<br />

ALM1: Alarm 1<br />

ALM2: Alarm 2<br />

ALM3: Alarm 3<br />

P.END: Program end output<br />

(See note 5.)<br />

RALM: Control output ON/<br />

OFF count alarm<br />

WR1: Work bit 1 (See note 6.)<br />

WR2: Work bit 2 (See note 6.)<br />

WR3: Work bit 3 (See note 6.)<br />

WR4: Work bit 4 (See note 6.)<br />

WR5: Work bit 5 (See note 6.)<br />

WR6: Work bit 6 (See note 6.)<br />

WR7: Work bit 7 (See note 6.)<br />

WR8: Work bit 8 (See note 6.)<br />

none<br />

o<br />

c-o<br />

alm1<br />

alm2<br />

alm3<br />

p.end<br />

ralm<br />

wr1<br />

wr2<br />

wr3<br />

wr4<br />

wr5<br />

wr6<br />

wr7<br />

wr8<br />

Appendix<br />

Parameters Characters Setting (monitor) value Display Default Unit Set value<br />

ALM1 None<br />

Auxiliary Output 2<br />

Assignment<br />

Auxiliary Output 3<br />

Assignment<br />

sub2 NONE: No assignment<br />

O: Control output<br />

(heating)<br />

C-O: Control output<br />

(cooling)<br />

ALM1: Alarm 1<br />

ALM2: Alarm 2<br />

ALM3: Alarm 3<br />

P.END: Program end output<br />

(See note 5.)<br />

RALM: Control output ON/<br />

OFF count alarm<br />

WR1: Work bit 1 (See note 6.)<br />

WR2: Work bit 2 (See note 6.)<br />

WR3: Work bit 3 (See note 6.)<br />

WR4: Work bit 4 (See note 6.)<br />

WR5: Work bit 5 (See note 6.)<br />

WR6: Work bit 6 (See note 6.)<br />

WR7: Work bit 7 (See note 6.)<br />

WR8: Work bit 8 (See note 6.)<br />

sub3 NONE: No assignment<br />

O: Control output<br />

(heating)<br />

C-O: Control output<br />

(cooling)<br />

ALM1: Alarm 1<br />

ALM2: Alarm 2<br />

ALM3: Alarm 3<br />

P.END: Program end output<br />

(See note 5.)<br />

RALM: Control output ON/<br />

OFF count alarm<br />

WR1: Work bit 1 (See note 6.)<br />

WR2: Work bit 2 (See note 6.)<br />

WR3: Work bit 3 (See note 6.)<br />

WR4: Work bit 4 (See note 6.)<br />

WR5: Work bit 5 (See note 6.)<br />

WR6: Work bit 6 (See note 6.)<br />

WR7: Work bit 7 (See note 6.)<br />

WR8: Work bit 8 (See note 6.)<br />

none<br />

o<br />

c-o<br />

alm1<br />

alm2<br />

alm3<br />

p.end<br />

ralm<br />

wr1<br />

wr2<br />

wr3<br />

wr4<br />

wr5<br />

wr6<br />

wr7<br />

wr8<br />

none<br />

o<br />

c-o<br />

alm1<br />

alm2<br />

alm3<br />

p.end<br />

ralm<br />

wr1<br />

wr2<br />

wr3<br />

wr4<br />

wr5<br />

wr6<br />

wr7<br />

wr8<br />

ALM2 None<br />

ALM3 None<br />

Character Select csel OFF, ON off, on ON None<br />

Soak Time Unit t-u M: Minutes; H: Hours m, h M None<br />

Alarm SP Selection alsp SP-M: Ramp set point sp-m, sp SP-M None<br />

SP: Set point