Parameter Flow<br />

338<br />

Appendix<br />

This section describes the parameters set in each level. Pressing the M Key at the last parameter in each level<br />

returns to the top parameter in that level.<br />

Protect Level<br />

c<br />

PID Setting Level<br />

Display PID Selection<br />

d.pid PID1<br />

1<br />

d.pid<br />

PID2<br />

2<br />

d.pid<br />

3 PID3<br />

M<br />

1.p<br />

8.0<br />

M<br />

1.i<br />

233.0<br />

M<br />

1.d<br />

40.0<br />

M<br />

1.olh<br />

105.0<br />

M<br />

1.oll<br />

-5.0<br />

M<br />

c<br />

1.aut<br />

1320.0<br />

M<br />

1.csc<br />

1.00<br />

M<br />

1.lba 0<br />

M<br />

Power ON<br />

<strong>Manual</strong><br />

Control Level<br />

Operation<br />

Level<br />

Initial Setting<br />

Level<br />

Advanced<br />

Function Setting<br />

Level<br />

d.pid PID8<br />

8<br />

c<br />

M<br />

8.p PID 8 Proportional Band<br />

8.0<br />

M<br />

8.i PID 8 Integral Time<br />

233.0<br />

M<br />

8.d PID 8 Derivative Time<br />

40.0<br />

M<br />

8.olh<br />

PID 8 MV Upper Limit<br />

105.0<br />

M<br />

8.oll<br />

PID 8 MV Lower Limit<br />

-5.0<br />

M<br />

8.aut PID 8 Automatic Selection<br />

1320.0 Range Upper Limit<br />

M<br />

8.csc<br />

PID 8 Cooling Coefficient<br />

1.00<br />

M<br />

8.lba PID 8 LBA Detection Time<br />

0<br />

c<br />

M<br />

Adjustment<br />

Level<br />

Communications<br />

Setting<br />

Level<br />

Bank Setting<br />

Level<br />

c<br />

c<br />

Display Bank Selection<br />

d.bnk<br />

Bank0<br />

0<br />

d.bnk<br />

Bank1<br />

1<br />

d.bnk 2<br />

Bank2<br />

M<br />

0.lsp<br />

0.0<br />

M<br />

0.pid 1<br />

M<br />

0.spr<br />

off<br />

M<br />

c<br />

0.a-1<br />

0.0<br />

M<br />

c 0.a1h<br />

0.0<br />

M<br />

c<br />

c<br />

0.a1l<br />

0.0<br />

M<br />

0.a-2<br />

0.0<br />

M<br />

c<br />

0.a2h<br />

0.0<br />

M<br />

0.a2l<br />

0.0<br />

M<br />

c<br />

c<br />

c<br />

c<br />

0.a-3<br />

0.0<br />

M<br />

0.a3h<br />

0.0<br />

M<br />

0.a3l<br />

0.0<br />

M<br />

0.sok<br />

1<br />

M<br />

0.wtb<br />

off<br />

M<br />

c<br />

PID Setting<br />

Level<br />

Press the O Key less than 1 s.<br />

Bank Setting Level<br />

d.bnk<br />

Bank7<br />

7<br />

M<br />

7.lsp Bank 7 SP<br />

0.0<br />

c<br />

c<br />

c<br />

M<br />

7.pid Bank 7 PID<br />

Set No.<br />

1<br />

Monitor/Setting<br />

Item Level<br />

Press the O Key less than 1 s. Press the O Key less than 1 s.<br />

M<br />

7.spr Bank 7 SP<br />

off<br />

Ramp Set Value<br />

M<br />

7.a-1<br />

Bank 7<br />

0.0 Alarm Value 1<br />

M<br />

c<br />

Bank 7<br />

7.a1h<br />

Alarm Value<br />

0.0<br />

Upper Limit 1<br />

M<br />

Bank 7<br />

c<br />

7.a1l<br />

Alarm Value<br />

0.0 Lower Limit 1<br />

M<br />

Set either of these parameters<br />

c<br />

7.a-2<br />

Bank 7<br />

0.0 Alarm Value 2<br />

M<br />

c<br />

Bank 7<br />

7.a2h<br />

Alarm Value<br />

0.0<br />

Upper Limit 2<br />

M<br />

Bank 7<br />

c<br />

7.a2l<br />

Alarm Value<br />

0.0 Lower Limit 2<br />

M<br />

c<br />

7.a-3<br />

Bank 7<br />

0.0 Alarm Value 3<br />

M<br />

c<br />

Bank 7<br />

7.a3h<br />

Alarm Value<br />

0.0<br />

Upper Limit 3<br />

M<br />

Bank 7<br />

c 7.a3l<br />

Alarm Value<br />

0.0 Lower Limit 3<br />

c<br />

Set either of these parameters<br />

Set either of these parameters<br />

M<br />

7.sok Bank 7 Soak Time<br />

1<br />

M<br />

7.wtb Bank 7 Wait Band<br />

off<br />

M