PID Setting Level Section 5-6<br />

5-6 PID Setting Level<br />

d.pid Display PID Selection<br />

Function<br />

Setting<br />

See<br />

216<br />

Power ON<br />

The PID setting level is used to make settings such as PID values for each<br />

PID set and MV limit values. Move to a particular PID set from the Display PID<br />

Set Selection parameter, which is displayed first in the PID setting level.<br />

Adjustment<br />

Operation Level<br />

Level<br />

Press the O Key<br />

for at least 1 s.<br />

PID Setting<br />

Level<br />

Bank Setting<br />

Level<br />

Temperature control<br />

being performed.<br />

This parameter is used to select the PID set for making the display settings.<br />

This parameter selects the PID set for which the display settings are to be<br />

made.<br />

Up to eight sets (1 to 8) can be used. The following items registered in<br />

each set: PID value, MV upper and lower limits, automatic selection range<br />

upper limit, cooling coefficient, and LBA detection time.<br />

Note The current PID set will be displayed. If you use the U and D Keys<br />

to change the PID set, the monitor function will be canceled.<br />

■ Related Parameters<br />

Display PID Selection<br />

d.pid PID1<br />

1<br />

d.pid<br />

2<br />

PID2<br />

d.pid<br />

3 PID3<br />

Bank No. (operation level): Page 179<br />

c<br />

PID Setting Level<br />

M<br />

1.p<br />

8.0<br />

M<br />

1.i<br />

233.0<br />

M<br />

1.d<br />

40.0<br />

M<br />

1.olh<br />

105.0<br />

M<br />

1.oll<br />

-5.0<br />

M<br />

c<br />

1.aut<br />

1320.0<br />

M<br />

1.csc<br />

1.00<br />

M<br />

1.lba<br />

0<br />

M<br />

Setting range Default<br />

1 to 8 See note.<br />

d.pid<br />

8 PID8<br />

c<br />

M<br />

8.p PID 8<br />

8.0 Proportional Band<br />

M<br />

8.i PID 8 Integral Time<br />

233.0<br />

M<br />

8.d PID 8 Derivative Time<br />

40.0<br />

M<br />

8.olh<br />

PID 8 MV Upper Limit<br />

105.0<br />

M<br />

8.oll<br />

PID 8 MV Lower Limit<br />

-5.0<br />

M<br />

c 8.aut PID 8<br />

1320.0 Automatic Selection<br />

Range Upper Limit<br />

M<br />

8.csc<br />

PID 8<br />

1.00 Cooling Coefficient<br />

M<br />

8.lba PID 8<br />

0 LBA Detection Time<br />

M