Initial Setting Level Section 5-9<br />

224<br />

Initial Setting Level<br />

c<br />

c<br />

in-t<br />

5<br />

M<br />

in-h<br />

100<br />

M<br />

in-l<br />

0<br />

M<br />

dp 0<br />

M<br />

d-u c<br />

M<br />

sl-h<br />

1300.0<br />

M<br />

sl-l<br />

-200.0<br />

M<br />

cntl<br />

pid<br />

M<br />

s-hc<br />

stnd<br />

M<br />

st<br />

on<br />

M<br />

ptrn<br />

off<br />

M<br />

pbnk<br />

7<br />

M<br />

Input Type<br />

Scaling Upper Limit<br />

Scaling Lower Limit<br />

Decimal Point<br />

For input type of analog<br />

Temperature Unit<br />

°C, °F<br />

For input type of<br />

temperature<br />

SP Upper Limit<br />

SP Lower Limit<br />

PID ON/OFF<br />

Limit the set point<br />

Standard or<br />

Heating/Cooling<br />

ST (Self-tuning)<br />

For input type of<br />

temperature, standard<br />

control, or PID<br />

Program Pattern<br />

Valid Program Bank<br />

When assigning PID<br />

or control output to<br />

ON/OFF output<br />

Page<br />

224<br />

226<br />

226<br />

226<br />

226<br />

227<br />

227<br />

228<br />

228<br />

228<br />

229<br />

230<br />

in-t Input Type<br />

Function<br />

c<br />

c<br />

c<br />

cp<br />

20<br />

M<br />

c-cp<br />

20<br />

M<br />

orev<br />

or-r<br />

M<br />

alt1 2<br />

M<br />

alh1<br />

0.2<br />

M<br />

alt2<br />

2<br />

M<br />

alh2<br />

0.2<br />

M<br />

alt3 2<br />

M<br />

alh3<br />

0.2<br />

M<br />

tr-t<br />

off<br />

M<br />

tr-h<br />

100.0<br />

M<br />

tr-l<br />

0.0<br />

M<br />

Control Period (Heating)<br />

Set the ON/OFF output<br />

cycle.<br />

Control Period (Cooling)<br />

Direct/Reverse Operation<br />

Alarm 1 Type<br />

Alarm 1<br />

Hysteresis<br />

Alarm 2 Type<br />

Alarm 2<br />

Hysteresis<br />

Alarm 3 Type<br />

Alarm 3<br />

Hysteresis<br />

Transfer Output Type<br />

Linear output<br />

Transfer Output<br />

Upper Limit<br />

Transfer Output<br />

Lower Limit<br />

Page<br />

230<br />

230<br />

231<br />

231<br />

233<br />

233<br />

233<br />

233<br />

234<br />

235<br />

236<br />

236<br />

o1-t<br />

4-20<br />

This parameter sets the type of sensor.<br />

When this parameter is changed, the set point limiter is changed to the<br />

defaults. If the limiter must be specified, set the SP Upper Limit and SP<br />

Lower Limit parameters (initial setting level) again.<br />

M<br />

ev-b<br />

1<br />

M<br />

ev-1 Event Input 1<br />

Assignment<br />

none<br />

M<br />

ev-2<br />

stop<br />

M<br />

Event Input 3<br />

ev-3 Assignment<br />

none<br />

M<br />

ev-4 Event Input 4<br />

Assignment<br />

none<br />

M<br />

clfl<br />

flot<br />

M<br />

calb<br />

off<br />

M<br />

mot<br />

30<br />

M<br />

sqr<br />

off<br />

M<br />

amov<br />

0<br />

M<br />

Linear Current Output<br />

Bank Numbers Used<br />

Event Input 2<br />

Assignment<br />

Closed/Floating<br />

Motor Calibration<br />

Travel Time<br />

Linear output<br />

Extraction of Square<br />

Root Enable<br />

Move to Advanced Function<br />

Setting Level:<br />

Displayed when initial setting/<br />

communications protect<br />

is set to 0.<br />

Page<br />

236<br />

237<br />

238<br />

238<br />

238<br />

238<br />

239<br />

240<br />

240<br />

240<br />

241<br />

Move by setting password (−169).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!