05.03.2013 Views

E5CNH E5AN-H E5EN-H Digital Controllers User's Manual - OMRON

E5CNH E5AN-H E5EN-H Digital Controllers User's Manual - OMRON

E5CNH E5AN-H E5EN-H Digital Controllers User's Manual - OMRON

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Adjustment Level Section 5-4<br />

Adjustment Level<br />

l.adj<br />

M<br />

at<br />

off<br />

M<br />

cmwt<br />

off<br />

M<br />

irda<br />

off<br />

M<br />

spmd<br />

lsp<br />

M<br />

ct1<br />

0.0<br />

M<br />

hb1<br />

0.0<br />

M<br />

oc1<br />

50.0<br />

M<br />

ct2<br />

0.0<br />

M<br />

hb2<br />

0.0<br />

M<br />

oc2<br />

50.0<br />

M<br />

lcr1<br />

0.0<br />

M<br />

hs1<br />

50.0<br />

M<br />

Adjustment Level<br />

Display<br />

Displayed only<br />

once when entering<br />

adjustment level.<br />

AT Execute/Cancel<br />

Communications<br />

Writing<br />

Infrared<br />

Communications<br />

Use<br />

SP Mode<br />

Heater Current 1<br />

Value Monitor<br />

Heater Burnout<br />

Detection 1<br />

Heater Overcurrent<br />

Detection 1<br />

Heater Current 2<br />

Value Monitor<br />

Heater Burnout<br />

Detection 2<br />

Heater Overcurrent<br />

Detection 2<br />

Leakage Current 1<br />

Monitor<br />

HS Alarm 1<br />

Page Page Page<br />

192<br />

192<br />

193<br />

193<br />

193<br />

194<br />

194<br />

195<br />

195<br />

196<br />

196<br />

198<br />

197<br />

c<br />

c<br />

c<br />

c<br />

lcr2<br />

0.0<br />

M<br />

hs2<br />

50.0<br />

M<br />

ins<br />

0.00<br />

M<br />

insh<br />

0.00<br />

M<br />

insl<br />

0.00<br />

M<br />

p<br />

8.0<br />

M<br />

i<br />

233.0<br />

M<br />

d<br />

40.0<br />

M<br />

c-sc<br />

1.00<br />

M<br />

c-db<br />

0.0<br />

M<br />

M<br />

M<br />

Set either<br />

of these<br />

parameters.<br />

PID settings<br />

<strong>Manual</strong> Reset Value<br />

of-r Clear the offset during<br />

50.0 stabilization of P or PD<br />

control.<br />

hys<br />

1.0<br />

Leakage Current 2<br />

Monitor<br />

HS Alarm 2<br />

Temperature Input Shift<br />

1-point shift<br />

Upper Limit<br />

Temperature<br />

Input Shift Value<br />

2-point shift<br />

Lower Limit<br />

Temperature<br />

Input Shift Value<br />

Proportional Band<br />

Integral Time<br />

Derivative Time<br />

Cooling Coefficient<br />

Heating/cooling<br />

Dead Band<br />

Hysteresis (Heating)<br />

Hysteresis settings<br />

198<br />

198<br />

199<br />

199<br />

199<br />

200<br />

200<br />

200<br />

201<br />

201<br />

202<br />

202<br />

chys<br />

1.0<br />

M<br />

soak<br />

1<br />

M<br />

wt-b<br />

off<br />

M<br />

mv-s<br />

0.0<br />

M<br />

mv-e<br />

0.0<br />

M<br />

sprt<br />

off<br />

M<br />

ol-h<br />

105.0<br />

M<br />

ol-l<br />

-5.0<br />

M<br />

orl<br />

0.0<br />

M<br />

db<br />

2.0<br />

M<br />

oc-h<br />

0.8<br />

M<br />

sqrp<br />

0.0<br />

M<br />

Hysteresis (Cooling)<br />

Soak Time<br />

Wait Band<br />

MV at Stop<br />

MV at PV Error<br />

SP Ramp Set Value<br />

MV Upper Limit<br />

MV Lower Limit<br />

MV Change Rate Limit 206<br />

Position Proportional<br />

Dead Band<br />

Open/Close Hysteresis<br />

Extraction of Square<br />

Root<br />

Low-cut Point<br />

202<br />

203<br />

203<br />

204<br />

204<br />

205<br />

205<br />

205<br />

207<br />

207<br />

207<br />

191