Advanced Function Setting Level Section 5-10<br />

out2 Control Output 2 Assignment<br />

Function<br />

Setting<br />

See<br />

262<br />

This parameter sets the function to be assigned to control output 2.<br />

Note (1) If c-o is assigned for standard control, a value equivalent to 0% will be<br />

output.<br />

(2) Can be selected for a relay output, voltage output (for driving SSR), or<br />

SSR output only.<br />

(3) The setting will be ignored when the Program Pattern parameter is set to<br />

OFF.<br />

(4) WR1 to WR8 are not displayed when the logic operation function is not<br />

used.<br />

(5) If the Standard or Heating/Cooling parameter is set to heating/cooling<br />

control, control automatically switches to c-o.<br />

■ Related Parameters<br />

There must a transfer output, or if<br />

there is no transfer output, control<br />

output 1 must be a linear output or<br />

control output 2 must not be a linear<br />

output. If control output 1 is not a linear<br />

output and control output 2 is a<br />

linear output, the transfer output type<br />

must be set to OFF.<br />

Setting range Default<br />

none: No function is assigned to control output 2. none<br />

o:<br />

c-o:<br />

Heating control output is output.<br />

Cooling control output is output. (See note 1.)<br />

(See note<br />

5.)<br />

alm1: Alarm 1 is output. (See note 2.)<br />

alm2: Alarm 2 is output. (See note 2.)<br />

alm3: Alarm 3 is output. (See note 2.)<br />

p.end: Program end is output. (See notes 2 and 3.)<br />

ralm: Control output ON/OFF count alarm (See note 2.)<br />

wr1: Work bit 1 (See notes 2 and 4.)<br />

wr2: Work bit 2 (See notes 2 and 4.)<br />

wr3: Work bit 3 (See notes 2 and 4.)<br />

wr4: Work bit 4 (See notes 2 and 4.)<br />

wr5: Work bit 5 (See notes 2 and 4.)<br />

wr6: Work bit 6 (See notes 2 and 4.)<br />

wr7: Work bit 7 (See notes 2 and 4.)<br />

wr8: Work bit 8 (See notes 2 and 4.)<br />

Standard or heating/cooling: Page 228, Program pattern: Page 229, (initial<br />

setting level)