346<br />
AT calculated gain, 248<br />
AT execute/cancel, 192<br />
AT hysteresis, 248<br />
auto/manual select addition, 256<br />
auto/manual switch, 178<br />
automatic cooling coefficient adjustment, 271<br />
automatic display return time, 250<br />
auxiliary output * open in alarm, 245<br />
auxiliary output 1 assignment, 263<br />
auxiliary output 2 assignment, 264<br />
auxiliary output 3 assignment, 265<br />
bank (0 to 7) PID set No., 210<br />
bank (0 to 7) SP, 210<br />
bank * alarm value 1, 211<br />
bank * alarm value 2, 212<br />
bank * alarm value 3, 213<br />
bank * alarm value lower limit 1, 212<br />
bank * alarm value lower limit 2, 213<br />
bank * alarm value lower limit 3, 214<br />
bank * alarm value upper limit 1, 212<br />
bank * alarm value upper limit 2, 213<br />
bank * alarm value upper limit 3, 214<br />
bank 0 to 7 SP ramp set value, 211<br />
bank No., 179<br />
bank numbers used, 237<br />
bank soak time, 215<br />
bank wait band, 215<br />
character select, 265<br />
closed/floating, 239<br />
cold junction compensation method, 252<br />
communications baud rate, 281<br />
communications data length, 281<br />
communications parity, 281<br />
communications stop bits, 281<br />
communications Unit No., 281<br />
communications writing, 193<br />
control output 1 assignment, 261<br />
control output 1 ON/OFF count alarm set value, 279<br />
control output 1 ON/OFF count monitor, 278<br />
control output 2 assignment, 262<br />
control output 2 ON/OFF count alarm set value, 279<br />
control output 2 ON/OFF count monitor, 278<br />
control period (cooling), 230<br />
control period (heating), 230<br />
cooling coefficient, 201<br />
dead band, 201<br />
decimal point, 226<br />
derivative time, 200<br />
direct setting of position proportional MV, 270<br />
direct/reverse operation, 231<br />
display bank selection, 210<br />
display PID selection, 216<br />
Index<br />
display refresh period, 277<br />
event input assignment *, 238<br />
extraction of square root enable, 240<br />
extraction of square root low-cut point, 207<br />
HB ON/OFF, 246<br />
heater burnout detection 1, 194<br />
heater burnout detection 2, 196<br />
heater burnout hysteresis, 247<br />
heater burnout latch, 246<br />
heater current 1 value monitor, 181, 194<br />
heater current 2 value monitor, 182, 195<br />
heater overcurrent detection 1, 195<br />
heater overcurrent detection 2, 196<br />
heater overcurrent hysteresis, 273<br />
heater overcurrent latch, 272<br />
heater overcurrent use, 272<br />
HS alarm 1, 197<br />
HS alarm 2, 198<br />
HS alarm hysteresis, 258<br />
HS alarm latch, 258<br />
HS alarm use, 257<br />
hysteresis (cooling), 202<br />
hysteresis (heating), 202<br />
infrared communications use, 193<br />
initial setting/communications protect, 172<br />
input digital filter, 249<br />
input error output, 251<br />
input shift type, 256<br />
input type, 224<br />
integral time, 200<br />
LBA band, 260<br />
LBA detection time, 259<br />
LBA level, 259<br />
leakage current 1 monitor, 183, 197<br />
leakage current 2 monitor, 183, 198<br />
limit cycle MV amplitude, 248<br />
linear current output, 236<br />
lower-limit temperature input shift value, 199<br />
manual MV limit enable, 270<br />
manual reset value, 202<br />
MB command logic switching, 252<br />
monitor/setting item, 274<br />
monitor/setting item display 1 to 5, 220<br />
motor calibration, 240<br />
move to advanced function setting level, 241<br />
move to calibration level, 280<br />
move to protect level, 172<br />
move to protect level time, 251<br />
MV at PV error, 204<br />
MV at stop, 204<br />
MV at stop and error addition, 256<br />
MV change rate limit, 206