Chapter 7 Basic Functions<br />

7.1.17 Stop method selection (Changing stop method)<br />

You can choose the method of stopping the motor when the inverter is given a stop command during operation.<br />

1) Decelerating Stop<br />

Group Code No. Function Display Setting Display Unit<br />

ADV 08 Stop Mode 0 Dec -<br />

This is a normal decelerating method. If no particular function is selected, the inverter decelerates to 0Hz and stops as<br />

follows.<br />

7.1.18 Stop after D.C. braking<br />

(in order to stop the motor when decelerating with direct current in pre-set frequency)<br />

If frequency reaches the set one, D.C. Braking stops the motor.<br />

1) How to stop by D.C. braking<br />

Group Code No. Function Display Setting Display Setting Range Unit<br />

ADV<br />

Frequency<br />

Operating<br />

Command<br />

08 Stop Mode 1 Dc-Brake 0~4 -<br />

14 Dc-Block Time - 0.10 0~60 -<br />

15 Dc-Brake Time - 1.00 0~200 -<br />

16 Dc-Brake Level - 50 200~200 -<br />

17 Dc-Brake Freq - 5.00 0~60 -<br />

If the frequency reaches pre-set frequency during deceleration, the motor is stopped by D.C. braking. Start decelerating<br />

with stop command and put direct voltage into the motor to stop if frequency reaches ADV-17 Dc-Brake Freq.<br />

ADV-14 Dc-Block Time : sets the time to block output of inverter before D.C. Braking. When inertia of load is big or<br />

ADV-17 Dc-Brake Freq is high, over current trips may occur due to current voltage to the motor. Therefore, it<br />

prevents from over current trips by controlling this time.<br />

ADV-15 Dc-Brake Time : sets the time to put current voltage to the motor.<br />

ADV-16 Dc-Brake Level : controls D.C. Braking. Rating current of the motor is a standard.<br />

ADV-17 Dc-Brake Freq : sets frequency to start D.C. Braking. It starts D.C. Braking when reaching<br />

pre-set frequency after inverter starts decelerating.<br />

Dec Time<br />

Notice<br />

When setting lower than frequence of D.C. Braking using Dwell frequency, Dwell operation is not available. Only D.C. Braking<br />

operates.<br />