How to Launch Easy Start<br />

Procedure Description<br />

1 Set CNF-61 Easy Start On as Yes.<br />

Select All in CNF-40 Parameter Init and initialize all the parameters of<br />

2<br />

the inverter.<br />

When the power of the inverter is first Off/On, Easy Start gets started.<br />

Through the following displays on the digital loader, set proper values.<br />

(If you press ESC on the digital loader, you can immediately get out of<br />

Easy Start)<br />

- Start Easy Set : select Yes.<br />

- CNF-01 Language Sel : select the language you want.<br />

- DRV-14 Motor Capacity : select the capacity of the motor.<br />

- BAS-11 Pole Number : select the pole number of the motor.<br />

3<br />

- BAS-15 Rated Volt : select the rated voltage of the motor.<br />

- BAS-10 60/50Hz Sel : select the rated frequency of the motor.<br />

- BAS-19 AC Input Volt : set the input voltage.<br />

- DRV-06 Cmd Source : selects the operating command method.<br />

- DRV-01 Cmd Frequency : select the operating frequency.<br />

Now you come back to the monitoring display. The minimum<br />

parameter to drive the motor having been set, the motor is operated by<br />

the operating command method set in DRV-06.<br />

8.1.33 Other Config (CNF) mode parameters<br />

Chapter 8 Applied Functions<br />

Group Code No. Function Display Initial Setting Display Unit<br />

CNF<br />

2 LCD Contrast - - -<br />

10 Inv S/W Ver - x.xx -<br />

11 Keypad S/W Ver - x.xx -<br />

12 KPD Title Ver - x.xx -<br />

30~32 Option-x Type - None -<br />

42 Changed Para 0 View All<br />

44 Erase All Trip 0 No -<br />

60 Add Title Del 0 No -<br />

62 WH Count Reset 0 No -<br />

74 Fan Time - 00:00:00 -<br />

75 Fan Time Rst 0 No -<br />

CNF-2 LCD Contrast : can adjust the LCD brightness of the digital loader.<br />

CNF-10 Inv S/W Ver, CNF-11 Keypad S/W Ver : can check the OS version of the inverter and digital loader.<br />

CNF-12 KPD Title Ver : can check the title version of the digital loader.<br />

CNF-30~32 Option-x Type : can check the type of the option board inserted in slots 1~3.<br />