52 0h1B34 Stall Level 1 stall level 1 30~250[%] 180 X 10-3 O O X O X<br />

53 0h1B35 Stall Freq 2 stall frequency 2<br />

stall frequency 1<br />

~stall frequency 2[Hz]<br />

60.00 O 10-3 O O X O X<br />

54 0h1B36 Stall Level 2 stall level 2 30~250[%] 180 X 10-3 O O X O X<br />

55 0h1B37 Stall Freq 3 stall frequency 3<br />

stall frequency 2<br />

~stall frequency 4[Hz]<br />

60.00 O 10-3 O O X O X<br />

56 0h1B38 Stall Level 3 stall level 3 30~250[%]<br />

stall frequency 3<br />

180 X 10-3 O O X O X<br />

57 0h1B39 Stall Freq 4 stall frequency 4 ~maximum frequency<br />

[Hz]<br />

60.00 O 10-3 O O X O X<br />

58 0h1B3A Stall Level 4 stall level 4 30~250[%] 180 X 10-3 O O X O X<br />

66 0h1B42 DB Warn %ED<br />

DB resistance<br />

warning level<br />

0~30[%] 0 O 10-11 O O O O O<br />

70 0h1B46<br />

Over SPD<br />

Freq<br />

overspeed<br />

judgment<br />

frequency<br />

20~130[%] 120.0 O 10-13 X X O X O<br />

72 0h1B48<br />

Over SPD<br />

Time<br />

overspeed<br />

judgment time<br />

0.01~10.00[sec] 0.01 O 10-13 X X O X O<br />

73 0h1B49<br />

Speed Dev<br />

Trip<br />

speed error failure<br />

0<br />

1<br />

No<br />

Yes<br />

0:No O 10-14 X X O X X<br />

74 0h1B4A<br />

Speed Dev<br />

Band<br />

speed error width<br />

2~maximum<br />

frequency[Hz]<br />

20.00 O 10-14 X X O X X<br />

75 0h1B4B<br />

Speed Dev<br />

Time<br />

speed error<br />

judgment time<br />

0.1~1000.0[sec] 1.0 O 10-14 X X O X X<br />

77 0h1B4D<br />

Enc Wire<br />

Check<br />

Encoder option<br />

connection check<br />

0<br />

1<br />

No<br />

Yes<br />

0:No O 10-14 X X O X O<br />

78 0h1B4E<br />

Enc Check<br />

Time<br />

Encoder<br />

connection check<br />

time<br />

0.1~1000.0[sec] 1.0 O 10-14 X X O X O<br />

79 0h1B4F FAN Trip Mode<br />

cooling fan failure<br />

selection<br />

0<br />

1<br />

Trip<br />

Warning<br />

0:Trip O 10-14 O O O O O<br />

movement 0 None<br />

80 0h1B50 Opt Trip Mode selection in case<br />

of option trip<br />

low voltage failure<br />

1<br />

2<br />

Free-Run<br />

Dec<br />

1:Free-Run O 10-16 O O O O O<br />

81 0h1B51 LVT Delay judgment delay<br />

time<br />

0~60.0[sec] 0.0 X 10-14 O O O O O<br />

* The grey code refers to hidden code, emerging only in case of setting of the code.<br />

Note 38)<br />

PRT-10 codes are displayed only when PRT-09(Retry Number) is set above “0”.<br />

Note 39)<br />

PRT-13~15 codes are displayed only when PRT-12(Lost Cmd Mode) is not “NONE”.<br />

Note 40)<br />

PRT-32~33 codes are displayed only when PRT-31(No Motor Trip is set as “Free-Run”.<br />

S<br />

L<br />

V<br />

C<br />

S<br />

L<br />

T<br />

13-38<br />

V<br />

C<br />

T

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!