8.1.4 3-Wire operation (if you want operation using Push button)<br />

Chapter 8 Applied Functions<br />

Group Code No. Function Display Setting Display Setting Range Unit<br />

DRV 06 Cmd Source 1 Fx/Rx - x 0~5 -<br />

IN 65~75 Px Define 14 3-Wire 0~48 -<br />

*Px : P1~P8, P9~P11 (Option)<br />

This is the function of operation by saving (Latch) the input signals as follows.<br />

Therefore, you can make simple configuration sequence circuit as shown below. For it to move, the minimum input time(t)<br />

of the input terminal should continue for more than 1mSec. If forward and reverse operating commands are<br />

simultaneously input, it stops.<br />

Frequency<br />

FX<br />

RX<br />

P8 (3-Wire)<br />

t<br />

Memorized<br />

frequency<br />

Output<br />

frequency<br />

P6(CLEAR)<br />

P7 (UP)<br />

Operation<br />

command(FX)<br />

P1 FX : IN-65<br />

P2 RX : IN-66<br />

P8<br />

CM<br />

3-Wire : IN-72<br />

8-7