BAS Group (PAR � BAS)<br />

No.<br />

Commu<br />

nication<br />

No.<br />

Function<br />

Display<br />

06 0h1206 Trq 2nd Src<br />

Name Setting Range Initial Value<br />

2 nd torque<br />

command method<br />

07 0h1207 V/F Pattern V/F pattern<br />

1 Keypad-2<br />

2 V1<br />

3 I1<br />

4 V2<br />

5 I2<br />

6 Int 485<br />

7 Encoder<br />

8 FieldBus<br />

9 PLC<br />

10 Synchro<br />

11 Binary Type<br />

12 Keypad-2<br />

0 Linear<br />

1 Square<br />

2 <strong>User</strong> V/F<br />

3 Square2<br />

0 Max Freq<br />

0:<br />

Keypad-1<br />

Chapter 13 Table of Functions<br />

Shift<br />

in<br />

Operation<br />

Page V<br />

/<br />

F<br />

Control Mode<br />

S<br />

L<br />

V<br />

C<br />

S<br />

L<br />

T<br />

V<br />

C<br />

T<br />

O 7-30 X X X O O<br />

0:Linear X 7-22 O O X X X<br />

08 0h1208 Ramp T Mode<br />

Acc/Dec standard<br />

frequency 1 Delta Freq<br />

0:Max Freq X 7-16 O O O X X<br />

0 0.01sec<br />

09 0h1209 Time Scale time unit setting 1 0.1sec 1:0.1sec X 7-17 O O O X X<br />

2 1sec<br />

10 0h120A 60/50 Hz Sel<br />

input power<br />

frequency<br />

0<br />

1<br />

60Hz<br />

50Hz<br />

0:60Hz<br />

X<br />

8-44 O O O O O<br />

11 0h120B Pole Number motor pole 2~48 X O O O O O<br />

12 0h120C Rated Slip rated sleep speed 0~3000[rpm] It depends X O O O O O<br />

13 0h120D Rated Curr motor rated current 1~200[A] on inverter X O O O O O<br />

14 0h120E Noload Curr<br />

motor<br />

no load current<br />

0.5~200[A]<br />

capacity<br />

X 8-11 O O O O O<br />

15 0h120F Rated Volt motor rated voltage 180~480[V] 0 X O O O O O<br />

16<br />

17<br />

18<br />

0h1210<br />

0h1211<br />

0h1212<br />

Efficiency<br />

Inertia Rate<br />

Trim Power %<br />

motor efficiency<br />

load inertial ratio<br />

Power display<br />

adjustment<br />

70~100[%]<br />

0~8<br />

70~130[%]<br />

It depends<br />

on inverter<br />

capacity<br />

X<br />

X<br />

O 9-3<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

19 0h1213<br />

220V 220<br />

AC<br />

Input Volt<br />

input power voltage 200~230[V]<br />

380~480[V] 440V 380<br />

O 8-44 O O O O O<br />

0 None<br />

1 All<br />

20 -<br />

Auto<br />

Tuning<br />

auto tuning<br />

2<br />

3<br />

ALL(Stdstl)<br />

Rs+Lsigma<br />

0:None X 8-17 X O O O O<br />

4 Enc Test<br />

5 Tr<br />