Chapter 8 Applied Functions<br />

8.1.3 Up-Down operation<br />

Group Code No. Function Display Setting Display Setting Range Unit<br />

ADV 65 U/D Save Mode 1 Yes 0~1 -<br />

IN<br />

8-6<br />

65~75 Px Define 17 Up 0~48 -<br />

65~75 Px Define 18 Down 0~48<br />

65~75 Px Define 20 U/D Clear 0~48 -<br />

*Px : P1~P8, P9~P11(Option)<br />

You can control deceleration and acceleration by using the multi-function terminal block. This can be used for the system<br />

that uses the upper/lower limit switch output signals of a flow meter, etc. as the acceleration/deceleration command of the<br />

motor.<br />

Group Code No. Function Display Code description<br />

ADV 65<br />

When setting<br />

multi-key jog<br />

REV key<br />

FWD key<br />

U/D<br />

Save Mode<br />

IN 65~75 Px Define<br />

DRV-12 (Acc time)<br />

DRV-11 (Jog frequency)<br />

DRV-13 (Dec time)<br />

DRV-11<br />

- In case of operating command (FX or RX terminal) OFF or a trip<br />

during steady speed operation of in case of power OFF, the<br />

operating frequency is automatically saved in the memory.<br />

- If operation command becomes ON or normal again, operation at<br />

set frequency is available. If you want to delete saved frequency,<br />

use the multi-function terminal block. Set one of the multi-function<br />

terminals at 20 U/D Clear and input the terminal in stop or steady<br />

speed operation, the frequency that was saved in up-down<br />

operation is deleted.<br />

- Sets the appropriate terminal function at 17 Up or 18 Down after<br />

selecting the terminal to use for up-down operation.<br />

- Acceleration follows Up signal during operation and when if is<br />

OFF, acceleration stops and steady speed operation follows.<br />

- Deceleration follows Down signal during operation and when if is<br />

Off, deceleration stops and steady speed operation follows.<br />

- If up and down signals are simultaneously given, acceleration and<br />

deceleration both stop.