Chapter 10 Protective Functions<br />

10-5<br />

Current<br />

Frequency<br />

PRT-51 Stall Freq 1 ~ PRT-58 Stall Level 4 : You can set the stall prevention level for each frequency band according<br />

to the load type. In addition, you can set the stall level above the base frequency. The lower limit and upper limit are set<br />

in the number sequence of the stall frequency. For example, the setting range of Stall Freq2 is between Stall Freq<br />

1(lower limit) and Stall Freq 3(upper limit).<br />

Stall level1<br />

acceleration<br />

DC voltage<br />

Frequency<br />

Caution<br />

The start timing is determined by the stall level 1 regardless of the other stall setting levels if the<br />

stall preventing function gets active during starting.<br />

Q1<br />

Stall level<br />

Stall level2<br />

Stall level3<br />

Stall level4<br />

Q1<br />

Stall level<br />

Deceleration<br />

Steady speed<br />

Stall Frequency 2 Stall Frequency 4<br />

Output<br />

Stall Frequency1 Stall Frequency 3 Frequency