8.1.22 2 nd Motor operation<br />

(when you want to do change operation of 2 monitors with one inverter)<br />

Chapter 8 Applied Functions<br />

During change operation, connecting different 2 monitors with one inverter, 2 nd operation is available when the terminal<br />

defined as the 2 nd function is 1 for the parameter of 2 nd monitor.<br />

Group Code No. Function Display Setting Display Unit<br />

IN 65~75 Px Define 26 2nd Motor -<br />

M2 04 M2-Acc Time - 5.0 Sec<br />

IN 65~75 Px Define : If you set the function item of the multi-function input terminal to 26 2 nd motor, PAR�M2 (2 nd<br />

motor group) is displayed in the parameter mode.<br />

If the multi-function terminal, which is set as 2 nd motor, is input, operation is carried out in the codes set as below.<br />

During operation, input of the multi-function terminal does not make the inverter operate in the 2 nd motor parameter.<br />

In M2-08(M2-Ctrl Mode), the operation modes of V/F PG, Vector are not available.<br />

To use M2-28(M2-Stall Lev), you must set PRT50(Stall Prevent) at the value you want to use.<br />

To use M2-29(M2-ETH 1min) and M2-30(M2-ETH Cont), you must set PRT40(ETH Trip Sel) at the value you want<br />

to use.<br />

Code No. Function Display Description<br />

04 M2-Acc Time Acceleration time<br />

05 M2-Dec Time Deceleration time<br />

06 M2-Capacity Motor capacity<br />

07 M2-Base Freq Rated frequency of the motor<br />

08 M2-Ctrl Mode Control mode<br />

10 M2-Pole Num Number of poles<br />

11 M2-Rate Slip Rated slip<br />

12 M2-Rated Curr Rated current<br />

13 M2-Noload Curr No-load current<br />

14 M2-Rated Volt Rated voltage of the motor<br />

15 M2-Efficiency Motor efficiency<br />

16 M2-Inertia Rt Inertia rate of load<br />

17 M2-Rs Stator resistance<br />

18 M2-Lsigma Lead inductance<br />

19 M2-Ls Stator inductance<br />

20 M2-Tr Rotor time constant<br />

25 M2-V/F Patt Output voltage pattern<br />

26 M2-Fwd Boost Forward torque boost<br />

27 M2-Rev Boost Reverse torque boost<br />