7.1.4 Sequential frequency setting<br />

Chapter 7 Basic Functions<br />

Group Code No. Function Display Setting Displayed Setting Range Unit<br />

DRV 07 Freq Ref Src - - - -<br />

BAS 50~64 Step Freq - x - - -- Hz<br />

IN<br />

65~75 Px Define<br />

7 Speed-L - -<br />

8 Speed-M - -<br />

9 Speed-H - -<br />

10 Speed-X - -<br />

89 InCheck Time - 1 - msec<br />

*Step Freq – x : Step Freq -1~15, Px: P1~P8, P9~P11 (Option)<br />

Sequential operation is available by using the multi-function terminal. Speed 0 frequency uses the frequency<br />

command selected in DRV Group No. 07.<br />

Enter the desired step frequency in codes 50~64 of BAS.<br />

Select the terminal to use as sequential input among multi-function terminals P1~P11 and set one of the sequential<br />

functions (Speed-L, Speed-M, Speed-H, Speed-X) for each.<br />

Speed-L, Speed-M, Speed-H and Speed-X are identified as binary codes and operation starts with the frequency set<br />

in BAS-50 ~ BAS-64 selected.<br />

If multi-function terminals P6, P7 and P8 are set at Speed-L, Speed-M and Speed-H respectively, you can operate it<br />

as follows. In case of Speed-X being used, you can set up to Speed 16 when the highest bit is Speed-X.<br />

Frequency<br />

P6<br />

P 7<br />

8<br />

P<br />

FX<br />

RX<br />

0<br />

1<br />

2<br />

3<br />

4 5 6<br />

7 8<br />

Speed FX or RX P8 P7 P6<br />

0 � - - -<br />

1 � - - �<br />

2 � - � -<br />

3 � - � �<br />

4 � � - -<br />

5 � � - �<br />

6 � � � -<br />

7 � � � �<br />

7-10