Extended Function Group (PAR � ADV)<br />

No. Communication<br />

No.<br />

Function<br />

Display<br />

Name Setting Range<br />

Chapter 13 Table of Functions<br />

Initial<br />

Value<br />

Shift in<br />

Operation<br />

Page V<br />

/<br />

F<br />

Control Mode<br />

24 0h1318 Freq Limit frequency limit<br />

0<br />

1<br />

No<br />

Yes<br />

0:No X 7-29 O O O X X<br />

25<br />

Note10) 0h1319 Freq Limit Lo<br />

frequency lower<br />

limit<br />

0~upper limit[Hz] 0.50 O 7-29 O O O X X<br />

26 0h131A Freq Limit Hi<br />

frequency upper<br />

limit<br />

0.5~maximum<br />

frequency[Hz]<br />

60.00 X 7-29 O O O X X<br />

27 0h131B Jump Freq frequency jump<br />

0<br />

1<br />

No<br />

Yes<br />

0:No X 7-29 O O O X X<br />

28<br />

Note 11) 0h131C Jump Lo 1<br />

jump frequency<br />

lower limit 1<br />

0~jumpfrequencyupper<br />

10.00<br />

limit1[Hz]<br />

Jump frequency lower<br />

O 7-29 O O O X X<br />

29 0h131D Jump Hi 1<br />

jump frequency<br />

upper limit 1<br />

limit1<br />

~maximum<br />

frequency[Hz]<br />

15.00 O 7-29 O O O X X<br />

30 0h131E Jump Lo 2<br />

jump frequency<br />

lower limit 2<br />

0~jumpfrequency<br />

upper limit2[Hz]<br />

Jump frequency lower<br />

20.00 O 7-29 O O O X X<br />

31 0h131F Jump Hi 2<br />

jump frequency<br />

upper limit 2<br />

limit2<br />

~maximum<br />

frequency[Hz]<br />

25.00 O 7-29 O O O X X<br />

32 0h1320 Jump Lo 3<br />

jump frequency<br />

lower limit 3<br />

0~jumpfrequency<br />

upper limit3[Hz]<br />

Jump frequency lower<br />

30.00 O 7-29 O O O X X<br />

33 0h1321 Jump Hi 3<br />

jump frequency<br />

upper limit 3<br />

limit3<br />

~maximum<br />

frequency[Hz]<br />

35.00 O 7-29 O O O X X<br />

41<br />

Note12) 0h1329 BR Rls Curr brake open current 0~180.0[%] 50.0 O 8-54 O O O X X<br />

42 0h132A BR Rls Dly<br />

brake open delay<br />

time<br />

0~10.00[sec] 1.00 X 8-54 O O O X X<br />

44 0h132C<br />

BR Rls Fwd brake open<br />

Fr<br />

forward frequency<br />

0~maximum<br />

frequency[Hz]<br />

1.00 X 8-54 O O O X X<br />

45 0h132D<br />

BR Rls Rev brake open<br />

Fr<br />

reverse frequency<br />

0~maximum<br />

frequency[Hz]<br />

1.00 X 8-54 O O O X X<br />

46 0h132E BR Eng Dly<br />

brake close delay<br />

time<br />

0~10[sec] 1.00 X 8-54 O O O X X<br />

47 0h132F BR Eng Fr<br />

brake close<br />

frequency<br />

0~maximum<br />

frequency[Hz]<br />

2.00 X 8-54 O O O X X<br />

50 0h1332<br />

energy saving<br />

E-Save Mode<br />

operation<br />

0<br />

1<br />

2<br />

None<br />

<strong>Manual</strong><br />

Auto<br />

0:None X 8-35 O O X X X<br />

51<br />

Note13) 0h1333 Energy Save<br />

energy saving<br />

amount<br />

0~30[%] 0 O 8-35 O O O X X<br />

60 0h133C<br />

Acc/Dec time<br />

Xcel Change<br />

exchange<br />

Fr<br />

frequency<br />

0~maximum<br />

frequency[Hz]<br />

0.00 X 7-18 O O O X X<br />

* The grey code refers to hidden code, emerging only in case of setting of the code.<br />

Note 10)<br />

ADV-25~26 is displayed only when ADV-24 (Freq Limit) is set as “Freq Limit”.<br />

Note 11)<br />

ADV-28~33 is displayed only when ADV-27 (Jump Freq) set as “Yes”.<br />

Note 12)<br />

ADV-41~47 is displayed only when a code of OUT-31~33 is set as “BR Control”.<br />

Note 13)<br />

ADV-51 is displayed only when ADV-50 (E-Save Mode) is set as values other than “None”.<br />

S<br />

L<br />

V<br />

C<br />

S<br />

L<br />

T<br />

V<br />

C<br />

T<br />