Input Terminal Block Function Group (PAR � IN)<br />

No.<br />

Commu<br />

nication<br />

No.<br />

Function<br />

Display<br />

Name Setting Range<br />

Initial<br />

Value<br />

Chapter 13 Table of Functions<br />

Shift<br />

in<br />

Oper<br />

ation<br />

Page V<br />

/<br />

F<br />

Control Mode<br />

65 0h1541 P1 Define<br />

P1 terminal function 0<br />

setting 1<br />

NONE<br />

FX<br />

1:FX X 7-12 O O O O O<br />

66 0h1542 P2 Define<br />

P2 terminal function<br />

2<br />

setting<br />

RX 2:RX X 7-12 X X O O O<br />

67 0h1543 P3 Define<br />

P3 terminal function<br />

3<br />

setting<br />

RST 5:BX X 10-15 O O O O O<br />

68 0h1544 P4 Define<br />

P4 terminal function<br />

4<br />

setting<br />

External Trip 4:Ex.t X 10-8 O O O O O<br />

69 0h1545 P5 Define<br />

P5 terminal function<br />

5<br />

setting<br />

BX 7:Sp-L X 10-15 O O O O O<br />

70 0h1546 P6 Define<br />

P6 terminal function<br />

6<br />

setting<br />

JOG 8:Sp-M X 8-4 O O O O O<br />

71 0h1547 P7 Define<br />

P7 terminal function<br />

7<br />

setting<br />

Speed-L 9:Sp-H X 7-10 O O O O O<br />

72 0h1548 P8 Define<br />

P8 terminal function<br />

8<br />

setting<br />

Speed-M 6:JOG X 7-10 O O O O O<br />

73<br />

Note24) 0h1549 P9 Define<br />

P9 terminal function<br />

9<br />

setting<br />

Speed-H 0: NONE X 7-10 O O O O O<br />

74<br />

75<br />

P10 terminal function<br />

0h154A P10 Define 10<br />

setting<br />

P11 terminal function<br />

0h154B P11 Define 11<br />

setting<br />

Speed-X<br />

XCEL-L<br />

0: NONE<br />

0: NONE<br />

X<br />

X<br />

7-10<br />

7-18<br />

O O O O O<br />

12 XCEL-M 7-18<br />

13 RUN Enable 8-8<br />

14 3-Wire 8-7<br />

15 2nd Source 7-30<br />

16 Exchange 8-42<br />

17 Up 8-6<br />

18 Down 8-6<br />

19 -reserved- -<br />

20 U/D Clear 8-6<br />

21 Analog Hold 7-10<br />

22 I-Term Clear 8-12<br />

23 PID Openloop 8-12<br />

24 P Gain2 8-12<br />

25 XCEL Stop 7-21<br />

26 2nd Motor 8-41<br />

27 Trv Offset Lo 8-53<br />

28 Trv Offset Hi 8-53<br />

29 Interlock 1 8-60<br />

30 Interlock 2 8-60<br />

31 Interlock 3 8-60<br />

32 Interlock 4<br />

8-60<br />

* The grey code refers to hidden code, emerging only in case of setting of the code.<br />

Note 24)<br />

IN73~75 codes are displayed only when the extended IO board is mounted.<br />

S<br />

L<br />

V<br />

C<br />

S<br />

L<br />

T<br />

V<br />

C<br />

T<br />

13-18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!