8.1.36 Traverse operation<br />

Group Code No. Function Display Initial Setting Display Unit<br />

01 App Mode 1 Traverse -<br />

08 Trv Amplit % - 0.0 %<br />

09 Trv Scramb % - 0.0 %<br />

APP 10 Trv Acc Time - 2.0 Sec<br />

11 Trv Dec Time - 3.0 Sec<br />

12 Trv Offset Hi - 0.0 %<br />

13 Trv Offset Lo - 0.0 %<br />

IN<br />

65~75<br />

65~75<br />

Px Define<br />

Px Define<br />

27<br />

28<br />

Trv Offset Lo<br />

Trv Offset Hi<br />

-<br />

-<br />

APP-01 App Mode : sets the application mode at No. 1 Traverse.<br />

The functions necessary for traverse operation are displayed.<br />

Chapter 8 Applied Functions<br />

APP-08 Trv Amplit % : selects the magnitude of the traverse operating frequency in percentage on the basis of the<br />

operating frequency.<br />

Operation frequency*<br />

TrvAmplit%<br />

Trv . Amp Frequency =<br />

100<br />

APP-09 Trv Scramb % : selects the magnitude of the scramble operating frequency and the frequency jump as<br />

shown below.<br />

Trv.<br />

Amp frequency*<br />

(100-<br />

TrvScramb%)<br />

Trv . Scr frequency = Trv.<br />

Amp frequency -<br />

100<br />

PP-10 Trv Acc Time, APP-11 Trv Dec Time : sets the Acc/Dec time of traverse operation.<br />

APP-12 Trv Offset Hi: If you select and input No. 28 Trv Offset Hi among the multi-function input terminal functions,<br />

operation is carried out at the frequency pattern that has increased by the value set at APP-12.<br />

Operation frequency*<br />

TrvOffsetHi<br />

Trv . OffsetHi frequency =<br />

100<br />

APP-13 Trv Offset Lo : If you select and input No. 27 Trv Offset Lo among the multi-function input terminal<br />

functions, operation is carried out at the frequency pattern that has decreased by the value set at APP-13.<br />

Operation frequency*<br />

TrvOffsetLo<br />

Trv . OffsetLo frequency =<br />

100<br />