8.1.35 Auto sequence operation<br />

Chapter 8 Applied Functions<br />

Group Code No. Function Display Initial Setting Display Unit<br />

APP 01 App Mode 4 Auto Sequenc -<br />

65~75 Px Define 41 SEQ-1 -<br />

65~75 Px Define 42 SEQ-2 -<br />

IN 65~75 Px Define 43 <strong>Manual</strong> -<br />

65~75 Px Define 44 Go Step -<br />

65~75 Px Define 45 Hold Step -<br />

OUT<br />

31~32<br />

33<br />

Relay 1, 2<br />

Q1 Define<br />

20<br />

21<br />

Step Pulse<br />

Seq Pulse<br />

-<br />

-<br />

APP-01 App Mode : If you select No. 4 Auto Sequence, the auto sequence group(AUT) is displayed in the<br />

parameter mode. you can set the type of the auto sequence, Acc/Dec time and frequency of each step and the<br />

rotation direction.<br />

IN-65~75 Px Define : Use the multi-function input terminal for auto sequence operation.<br />

41 : SEQ-L, 42 : SEQ-M<br />

The sequence type of the auto sequence operation is selected. Up to 2 sequence operations are available with<br />

different data set for each. If the terminal selected as SEQ-1 is input, the operation is carried out with the data set in<br />

sequence 1. If the terminal selected as SEQ-2 is input, the operation is carried out with the data set in sequence 2.<br />

43 : <strong>Manual</strong><br />

If the terminal set as No. 43 <strong>Manual</strong> is input during stop in the auto sequence operation mode, the operating<br />

command and frequency command respectively set in DRV06(Cmd Source) and DRV07(Freq Ref Src) will apply.<br />

44 : Go Step<br />

The auto sequence operating method is selected. If you select Auto-B in AUT-01 code, this is used as the command<br />

of step shift.<br />

45 : Hold Step<br />

During operation with AUT-01 Auto Mode set at Auto-A, if Hold Step terminal is input, the last step can be maintained.<br />

If you select No. 19 Step Pulse among the function items of OUT-31~33, the output signals are output in pulses<br />

every time each step changes during auto sequence operation. The pulse width is 100mSec. If you select No. 20<br />

Seq Pulse and the pulse is output at the last step where a cycle of sequence 1 or 2, the pulse width is 100mSec.<br />

Group Code No. Function Display Initial Setting Display Unit<br />

AUT<br />

01 Auto Mode 0 Auto-A -<br />

02 Auto Check - 0.08 Sec<br />

04 Step Number - 8 -<br />

10 Seq 1/1 Freq - 11.00 Hz<br />

11 Seq 1/1 XcelT - 5.0 Sec<br />

12 Seq 1/1 StedT - 5.0 Sec<br />

13 Seq 1/1 Dir 1 Forward -<br />

14 Seq 1/2 Freq - 21.00 Hz<br />

Displayed repeatedly as the number of set steps<br />