DRV Group (PAR � DRV)<br />

No. Communication<br />

No.<br />

Function Display Name Setting Range Initial Value<br />

Chapter 13 Table of Functions<br />

Shift in<br />

Operation<br />

Page V<br />

/<br />

F<br />

Control Mode<br />

10 0h110A Torque Control<br />

torque<br />

control<br />

0<br />

1<br />

No<br />

Yes<br />

0:No X 8-31 X X X O O<br />

11 0h110B Jog Frequency<br />

jog<br />

frequency<br />

jog<br />

0.5~maximum<br />

frequency[Hz]<br />

10.00 O 8-4 O O O O O<br />

12 0h110C Jog Acc Time operation<br />

Acc time<br />

jog<br />

0~600[sec] 20.0 O 8-4 O O O O O<br />

13 0h110D Jog Dec Time operation<br />

Dec time<br />

0~600[sec]<br />

0:0.2kW, 1:0.4kW<br />

2:75kW, 3:1.5kW<br />

30.0 O 8-4 O O O X X<br />

4:2.2kW, 5:3.7kW<br />

6:5.5kW, 7:7.5kW<br />

8:11kW, 9:15kW<br />

8-11<br />

14 0h110E Motor Capacity<br />

motor<br />

capacity<br />

10:18.5kW,11:22kW<br />

12:30kW,13:37kW<br />

14:45kW,15:55kW<br />

depends on<br />

inverter<br />

capacity<br />

X<br />

O O O O O<br />

16:75kW, 17:90kW<br />

18:110kW,<br />

19:132kW<br />

20:160kW,<br />

21:185kW<br />

8-17<br />

torque 0 <strong>Manual</strong><br />

15 0h110F Torque Boost boost<br />

method<br />

1 Auto<br />

0:<strong>Manual</strong> X 7-23 O X X X X<br />

16<br />

Note2)<br />

0h1110 Fwd Boost<br />

horward<br />

torque<br />

boost<br />

0~15[%]<br />

Below 75kW 2.0<br />

Above 90kW 1.0<br />

X 7-23 O X X X X<br />

reverse<br />

Below 75kW 2.0<br />

17 0h1111 Rev Boost torque 0~15[%]<br />

X 7-23 O X X X X<br />

boost<br />

Above 90kW 1.0<br />

18 0h1112 Base Freq<br />

base<br />

frequency<br />

30~400[Hz] 60.00 X 7-21 O O O O O<br />

19 0h1113 Start Freq<br />

starting<br />

frequency<br />

0.01~10[Hz] 0.50 X 7-21 O X X X X<br />

20 0h1114 Max Freq<br />

maximum<br />

frequency<br />

40~400 60.00 X 7-28 O O O O O<br />

21 0h1115 Hz/Rpm Sel<br />

speed unit<br />

selection<br />

0<br />

1<br />

Hz Display<br />

Rpm Display<br />

0:Hz O 9-4 O O O O O<br />

* The grey code refers to hidden code, emerging only in case of setting of the code.<br />

Note 2)<br />

DRV-16-17 code is displayed only when DRV-15 (Torque Boost) code value is “<strong>Manual</strong>”.<br />