14.11.2012 Views

SV-iS7 User Manual - Inverter Drive Supermarket

SV-iS7 User Manual - Inverter Drive Supermarket

SV-iS7 User Manual - Inverter Drive Supermarket

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 8 Applied Functions<br />

8-18<br />

Input<br />

voltage<br />

400<br />

Motor<br />

capacity<br />

[kW]<br />

Rating<br />

current<br />

[A]<br />

No load<br />

current<br />

[A]<br />

Rating slip<br />

frequency<br />

[Hz]<br />

Stator<br />

resistance<br />

[Ω]<br />

15 53.6 15.5 1.00 0.084 1.118<br />

18.5 65.6 19.0 1.00 0.068 0.819<br />

22 76.8 21.5 1.00 0.056 0.948<br />

30 104.6 29.3 1.00 0.042 0.711<br />

0.2 0.7 0.5 3.33 28.00 121.2<br />

0.4 1.4 0.8 3.33 14.0 80.8<br />

0.75 2.0 1.0 3.00 7.81 53.9<br />

1.5 3.7 1.5 2.67 3.52 27.9<br />

2.2 5.0 1.9 2.33 2.520 19.95<br />

3.7 8.0 2.9 2.33 1.500 13.45<br />

5.5 12.1 4.1 1.50 0.940 9.62<br />

7.5 16.3 5.4 1.33 0.520 8.53<br />

11 23.2 7.2 1.00 0.360 4.48<br />

15 31.0 9.0 1.00 0.250 3.38<br />

18.5 38.0 11.0 1.00 0.168 2.457<br />

22 44.5 12.5 1.00 0.168 2.844<br />

30 60.5 16.9 1.00 0.126 2.133<br />

37 74.4 20.1 1.00 0.101 1.704<br />

45 90.3 24.4 1.00 0.084 1.422<br />

55 106.6 28.8 1.00 0.069 1.167<br />

75 141.6 35.4 1.00 0.050 0.852<br />

90 167.6 41.9 1.00 0.039 0.715<br />

110 203.5 48.8 1.00 0.032 0.585<br />

132 242.3 58.1 1.00 0.027 0.488<br />

160 290.5 69.7 1.00 0.022 0.403<br />

185 335.0 77.0 1.00 0.021 0.380<br />

1) Motor Parameter Tuning (Rs, Lsigma, Ls, Tr, Noload curr)<br />

Leakage<br />

inductance<br />

[mH]<br />

BAS-20 Auto Tuning : Selects the type of auto tuning and implements auto tuning. Auto tuning starts if you select one of<br />

the items below and press PROG.<br />

0 : None<br />

Displays the initial auto tuning item. After auto tuning is completed, that it is finished is displayed.<br />

1 : ALL<br />

The motor parameter is measured with the motor rotating. The stator resistance(Rs), leak inductance(Lsigma), stator<br />

inductance(Ls), no-load current(Noload Curr) and rotor time constant(Tr) are all measured. When the encoder option card<br />

is mounted, the encoder state is also measured. For encoder state measurement, the related functions of the encoder<br />

should be rightly set. For setting the control mode at vector control, set the auto tuning item at No. 1 ALL. If load is<br />

connected to the motor axis, the parameter might not be correctly measured because the motor measures the parameter<br />

while rotating. Therefore, for correct measurement, remove the load attached to the motor axis before use. If Control<br />

Mode(DRV-09) is Sensorless-2, the rotor time constant(Tr) is tuned while it is static.