Chapter 8 Applied Functions<br />

8.1.5 Safe operation mode (if you want to limit operation through Terminal Input)<br />

Group Code No. Function Display Setting Display Setting Range Unit<br />

ADV<br />

8-8<br />

70 Run En Mode 1 DI Dependent - -<br />

71 Run Dis Stop 0 Free-Run 0~2 -<br />

72 Q-Stop Time - 5.0 0~600 sec<br />

IN 65~75 Px Define 13 Run Enable 0~48 -<br />

This is the function of setting the operating command for it to be effective by using the multi-function input terminal.<br />

Group Code No. Function Display Code description<br />

IN 65~75 Px Define<br />

ADV<br />

70<br />

71<br />

72<br />

n (P4)<br />

Operation<br />

command (P1)<br />

Run<br />

En Mode<br />

Run<br />

Dis Stop<br />

Q-Stop<br />

Time<br />

ADV-71<br />

(0:setting Free-Run)<br />

selects the terminal to operate at No. 13 Safe Operation Mode<br />

Run Enable among the multi-function input terminals.<br />

(if setting only multi-function terminals as Run Enable, Safe<br />

Operation is not active)<br />

if setting at No. 1 DI Dependent, the operating commands it<br />

identified through the multi-function input terminal.<br />

Set at No. 0 Always Enable, the safe operation mode is not active.<br />

sets the motions of the inverter when the multi-function input<br />

terminal set at safe operation mode is OFF.<br />

0 : Free-Run<br />

Blocks the inverter output when the multi-function terminal is OFF.<br />

1 : Q-Stop<br />

Decelerates at the decelerating time(Q-Stop Time) used in safe<br />

operation mode. Operation resumes after the operation command<br />

is input once again even if the multi-function terminal is ON.<br />

2 : Q-Stop Resume<br />

Decelerates at the decelerating time(Q-Stop Time) of safe<br />

operation mode. Normal operation resumes when the multifunction<br />

terminal is input again with the operating command ON.<br />

If ADV-71 Run Dis Stop is set at No.1 Q-Stop or No.2 Q-Stop<br />

Resume, the decelerating time is set.<br />

ADV-71<br />

(1:setting Q-Stop)<br />

ADV-71<br />

(1:setting Q-Stop Resume)