Chapter 9 Monitor Functions<br />

* WHour Counter: Describes for No.5 WHour Counter (electricity consumed by inverter) among the aforementioned<br />

Monitor items. Electricity consumption is calculated with voltage and current, and it is accumulated the calculated<br />

electricity every 1 second.<br />

The way of Electricity consumption display is followed description.<br />

1. Below 1000kW, the unit is kW and it is displayed like a 999.9 kW.<br />

2. Between 1 ~ 99 MW, the unit is MW and it is displayed like a 99.99MWh.<br />

3. Between 100 ~ 999 MW, the unit is MW and it is displayed like a 999.9 MWh.<br />

4. Above 1000 MW, the unit is MW and it is displayed like a 9999 MWh and can be displayed to 65535 MW.<br />

5. Above 65535 MW, it is initialized to 0 and the unit becomes to kW and displayed like 999.9 kW.<br />

6. In case of CNF-62 WH Count Reset to YES, user can clear the electricity consumption.<br />

3) Load Speed Display Selection<br />

Mode Group<br />

Code<br />

No.<br />

Function Display Initial Setting Unit<br />

61 Load Spd Gain - 100.0 %<br />

PAR ADV 62 Load Spd Scale 0 X 1 -<br />

63 Load Spd Unit 0 rpm -<br />

ADV-61 Load Spd Gain : selects No. 24 Load Speed among the monitor items described above and displays the<br />

actual number of rotations by computing the gear ratio when the motor axis and load are connected by a belt and so<br />

on.<br />

ADV-62 Load Spd Scale : selects to what place of decimals to display No. 24 Load Speed among the monitor<br />

items(x1~x0.0001).<br />

ADV-63 Load Spd Unit : selects the unit of No. 24 Load Speed among the monitor items. selects one of<br />

RPM(Revolution Per Minute) and MPM(Meter Per Minute).<br />

For example, if the speed is 300 [mpm] at 800[rpm] and if you want to display the value, set ADV-61(Load Spd Gain)<br />

at“375%”. In addition, if you want it to be displayed to the first place of the decimals, set ADV-63(Load Spd Scale) at<br />

“X 0.1”. Now “300.0 mpm” is displayed on the keypad display instead of “800rpm” for No. 24 Load Speed.<br />

4) Hz / Rpm Display Selection<br />

Mode Group Code No.<br />

Function<br />

Display<br />

Initial Setting Unit<br />

PAR<br />

DRV<br />

BAS<br />

21<br />

11<br />

Hz / Rpm Sel<br />

Pole Number<br />

0<br />

-<br />

Hz<br />

4<br />

-<br />

-<br />

DRV-21 Hz / Rpm Sel : can convert all the parameters of which the unit is Hz into RPM or reversely. The Pole<br />