8.1.6 Dwell operation<br />

Chapter 8 Applied Functions<br />

Group Code No. Function Display Initial Value Setting Range Unit<br />

ADV<br />

20 Acc Dwell Freq - 5.00<br />

Starting frequency ~<br />

Maximum frequency<br />

Hz<br />

21 Acc Dwell Time - 0.0 0~10 Sec<br />

22 Dec Dwell Freq - 5.00<br />

Starting frequency ~<br />

Maximum frequency<br />

Hz<br />

23 Dec Dwell Time - 0.0 0~10 Sec<br />

If the operating command is input, the inverter operates at steady speed for the acceleration dwell time at the set<br />

acceleration dwell frequency and resumes acceleration. If the stop command is input, inverter operates at steady speed for<br />

the deceleration dwell time at the set deceleration dwell frequency after deceleration and then stops.<br />

If control mode (DRV-09 Control Mode) is used as the V/F mode, it can be used for opening the brake after operation at<br />

the dwell frequency before the mechanical brake is opened at the lifting load.<br />

* Detailed description about Dwell operation<br />

Caution<br />

Be careful that dwell operation at a frequency higher than the rated slip of the motor with the load shown in<br />

the case above might adversely affect the life of the motor or damage the motor due to over current through<br />

the motor.<br />

O u t p u t<br />

F r e q u e n c y<br />

P x ( S E Q - L )<br />

P x ( S E Q -<br />

M )<br />

O u t p u t<br />

F r e q u e n c y<br />

P x ( S E Q - L )<br />

P x ( G o -<br />

S t e p )<br />

S e q u e n c e<br />

1<br />

This function is useful in hoisting applications to get enough Torque before a releasing mechanical brake. <strong>Inverter</strong><br />

accelerates to Dwell frequency during set time after run command input. It operates as set speed after the lapse of the<br />

Dwell acceleration run time (Acc Dwell Time) which is set in Dwell run frequency. If Stop command is input during run,<br />

inverter will decelerate as Dwell run frequency and then it will stop as previous deceleration time after the set Dwell<br />

deceleration run time (Dec Dwell Time). If the dwell time is set at ‘0’, this function is not available. Acc Dwell<br />

command is effective only first command input so it is not available in case the frequency passes by Acc Dwell<br />

frequency while resume the acceleration on stop. Dec Dwell operates when frequency passes by Dec Dwell<br />

frequency on stop command input and it is not operated on simple deceleration of frequency. Dwell operation is not<br />

operated when External brake control function is activated.<br />

A u t o - A<br />

A u t o - B<br />

S e q u e n c y<br />

2<br />

8-9