Chapter 9 Monitor Functions<br />

4 : FDT-4<br />

9-12<br />

Group Code No. Function Display Initial Setting Unit<br />

OUT<br />

57 FDT Frequency - 30.00 Hz<br />

58 FDT Band (Hz) - 10.00 Hz<br />

Can operate setting the conditions of acceleration and deceleration at the same time.<br />

Acceleration : operating frequency >= detected frequency<br />

Deceleration : operating frequency > (detected frequency - detected frequency/2)<br />

Group Code No. Function Display Initial Setting Unit<br />

OUT<br />

57<br />

58<br />

FDT Frequency<br />

FDT Band (Hz)<br />

-<br />

-<br />

30.00<br />

10.00<br />

Hz<br />

Hz<br />

5 : Over Load (motor overload)<br />

Active when the motor is given overload.<br />

6 : IOL (inverter overload)<br />

Active in case of a failure for inverse time characteristic protection against inverter overload.<br />

7 : Under Load (underload warning)<br />

Active in case of underload warning.<br />

8 : Fan Warning (fan failure)<br />

Set ‘8: Fan Warning’ at multi-function output and it will be Activated when there is a problem with the cooling fan.<br />

9 : Stall (motor stall)<br />

Frequency<br />

Q1<br />

Operating<br />

command<br />

Frequency<br />

Q1 Operating<br />

command<br />

30Hz<br />

30Hz<br />

Active in case of a stall caused by the motor overload.<br />

35Hz<br />

25Hz<br />

25Hz