Chapter 7 Basic Functions<br />

6) Frequency setting by Encoder Option Card (If you want use pulse input to frequency command)<br />

Group Code No. Function Display Setting Displayed Setting Frequency Unit<br />

DRV 07 Freq Ref Src 7 Encoder - -<br />

IN 01 Freq at 100% - 60.00 0.00~Max. Freq. Hz<br />

APO<br />

01 Enc Opt Mode 2 Reference 0~2 -<br />

04 Enc Type Sel 0 - 0~2 -<br />

05 Enc Pulse Sel 2 A 0~2 -<br />

06 Enc Pulse Num - - 10~4096 -<br />

09 Pulse Monitor - - - kHz<br />

10 Enc Filter - 10 0~10000 msec<br />

11 Enc Pulse x1 - 0.0 0~100 kHz<br />

12 Enc Perc Y1 - 0.00 0~100 %<br />

13 Enc Pulse x2 - 100.0 0~100 kHz<br />

14 Enc Perc y2 - 100.00 0~100 %<br />

If you mount the encoder option card on the main body of the inverter, the code is displayed from APO-01.<br />

APO-01 Enc Opt Mode, APO-05 Enc Pulse Sel: Select No.2 Reference for APO-01 in order to set the frequency with<br />

the encoder. Set APO-05 at No.2 A.<br />

APO-04 Enc Type Sel, APO-06 Enc Pulse Sel: inputs the output method and number of pulses in harmony with the<br />

encoder specification.<br />

APO-10 Enc Filter ~ APO-14 Enc Perc y2: sets the filter time constant and minimum and maximum input frequency of<br />

the encoder input. The output frequency corresponding to the encoder input frequency is the same as that of voltage (V1)<br />

or current (I1) input.<br />

APO-09 Pulse Monitor: displays the frequency of the pulse which is input when APO-01 Enc Opt Mode is set as<br />

Reference.<br />

7) Frequency setting by RS-485 Communication: Int 485<br />

Group Code No. Function Display Setting Displayed Setting Frequency Unit<br />

DRV 07 Freq Ref Src 6 Int 485 - -<br />

01 Int485 St ID - 1 0~250 -<br />

0 ModBus RTU 0~2 -<br />

02 Int485 Proto 1 ModBus ASCII 0~2 -<br />

COM<br />

04 Int485 BaudR<br />

2<br />

3<br />

LS Inv 485<br />

9600<br />

0~2<br />

1200~38400<br />

-<br />

bps<br />

0 D8 / PN / S1 0~3 -<br />

07 Int485 Mode<br />

1<br />

2<br />

D8 / PN / S2<br />

D8 / PE / S1<br />

0~3<br />

0~3<br />

-<br />

-<br />

3 D8 / PO / S1 0~3 -<br />

7-8