11.1.7 Virtual multi-function input setting<br />

Chapter 11 Communication Function<br />

Group Code No. Function Display Setting Display Unit<br />

COM<br />

70~85 Virtual DI x 0 None -<br />

86 Virt DI Status - - -<br />

COM-70~85: You can control multi-function input by communication (common area h0385: see Page 11-28). The<br />

function which is set will be operated at each bit after set the function at COM-70~85 and then set the bit which is set<br />

the function wanted to 1 at 0h0322. Note that it should be set DRV-06, CMD source as Run command source.<br />

Ex) If you want to send Fx command with controlling virtual multi-function input command area by Int485, Fx function<br />

is triggered if 0h0001 is inputted in the 0h0322 after COM-70 (Virtual DI 1) is set to FX. It works without relation to<br />

IN65~75 (Px Define) and impossible to overlap setting. You can check the status of virtual multi-function input at<br />

COM-86.<br />

11.1.8 Caution in parameter setting for communication<br />

Group Code No. Function Display Setting Display Unit<br />

CNF 48<br />

Parameter<br />

Save<br />

0<br />

1<br />

-No-<br />

-Yes-<br />

-<br />

-<br />

Set the common area parameter or keypad parameter by communication, start the inverter. Turn off and then on the<br />

inverter, and the setting state goes back to the state before it was set by communication.<br />

If you select Yes at CNF48 Parameter Save, all the currently set values are saved in the inverter and will remain<br />

unchanged even if you turn off and on the unit.<br />

If you set 0h03E0 address at 0 by communication and then at 1, all the currently set parameter values are saved in<br />

the inverter and will remain unchanged even if you turn off and on the unit. However, if it is set at 1 and you switch it to<br />

0, it’s not effective.<br />

11.1.9 Communication frame monitoring.<br />

You can easily check the state (normal, CRC/Checksum error, other errors, etc.) of the communication frame being<br />

received from the master by using the digital loader.<br />

Group Code No. Function Display Setting Display Unit<br />

COM<br />

90 Comm Mon Sel 0 Int 485 -<br />

91 Rcv Frame Num - - -<br />

92 Err Frame Num - - -<br />

93 NAK Frame Num - - -<br />

94 Comm Update<br />

0<br />

1<br />

-No-<br />

-Yes-<br />

-<br />