Chapter 6 How to use Keypad<br />

2) Parameter setting in other modes and groups<br />

This gives an example of changing frequency in the <strong>Drive</strong> Group of Parameter Mode. You can do so too in other<br />

modes or groups.<br />

6-16<br />

PAR DRV N STP 0.00Hz<br />

00 Jump Code<br />

9 CODE<br />

01 Cmd Frequency<br />

0.00 Hz<br />

02 Cmd Torque<br />

0.0 %<br />

PAR DRV N STP 0.00Hz<br />

00 Jump Code<br />

9 CODE<br />

01 Cmd Frequency<br />

0.00 Hz<br />

02 Cmd Torque<br />

0.0 %<br />

PAR DRV N STP 0.00Hz<br />

01 Cmd Frequency<br />

0.00 Hz<br />

0.50 ~ 60.00 Hz<br />

D:0.00 C:0.00<br />

PAR DRV N STP 0.00Hz<br />

01 Cmd Frequency<br />

10.00 Hz<br />

0.50 ~ 60.00 Hz<br />

D:0.00 C:0.00<br />

PAR DRV N STP 0.00Hz<br />

00 Jump Code<br />

9 CODE<br />

01 Cmd Frequency<br />

10.00 Hz<br />

02 Cmd Torque<br />

0.0 %<br />

- This is the initial display of Parameter Mode.<br />

- Press Down key.<br />

- You have shifted to 01 frequency setting code.<br />

- Press PROG.<br />

- The cursor flashes so that you can enter frequency.<br />

- If you want to set the frequency at 10Hz, move the cursor to the desired place<br />

using Left/Right keys.<br />

- Enter 10Hz using Up key and press PROG.<br />

- The desired frequency has been changed to 10Hz.