Chapter 9 Monitor Functions<br />

Function 8.1.19 Speed search operation.<br />

20 : Step Pulse, 21 : Seq Pulse (auto sequence operation)<br />

9-14<br />

Active after the advance step of the auto sequence operation and a cycle of the operating sequence.<br />

22 : Ready (stand by for operating command)<br />

Active when the inverter is normally operating and ready to operate waiting for operating command from outside.<br />

23 : Trv ACC, 24 : Trv DEC<br />

Trv ACC produces signals when the accelerating frequency is reached during traverse operation.<br />

Trv DEC produces signals when the decelerating frequency is reached.<br />

25 : MMC<br />

Group<br />

Code<br />

No.<br />

Function<br />

Display<br />

Initial Setting Unit<br />

APP 01 App Mode 1 Traverse -<br />

This is used for multi-motor control. This takes necessary actions for multi-motor control if you set the relay 1 and 2<br />

and multi-function output(Q1) at MMC and APP-01 App Mode at No. 3 MMC.<br />

26 : Zspd Dect<br />

Group<br />

Code<br />

No.<br />

Function<br />

Display<br />

Initial Setting Unit<br />

APP 01 App Mode 3 MMC -<br />

This is used where the motor rotation speed is 0(rpm) during operation with the control mode set as vector.<br />

Group<br />

Code<br />

No.<br />

Function<br />

Display<br />

Initial Setting Unit<br />

DRV 09 Control Mode 4 Vector -<br />

CON<br />

70<br />

ZSD<br />

Frequency<br />

- 2.00 Hz<br />

71 ZSD Band (Hz) - 1.00 Hz<br />

OUT 33 Q1 Define<br />

2<br />

5<br />

Zspd Dect -<br />

Revolution of Motor<br />

Q1(Zspd Dect)<br />

CON-70+CON_71<br />

CON-70 - CON-71<br />

The relay operating on the basis of the revolution of the motor(encoder signal), error might occur at the time of<br />