13.1.7 Parameter mode – Communication function group (�COM)<br />

Communication Function Group (PAR � COM)<br />

No. Communic<br />

ation No.<br />

Function Display Name Setting Range Initial Value<br />

Chapter 13 Table of Functions<br />

Shift<br />

in<br />

Oper<br />

ation<br />

Page<br />

V<br />

/<br />

F<br />

Control Mode<br />

00 - Jump Code jump code<br />

built-in<br />

0~99 20 O - O O O O O<br />

01 0h1701 Int485 St ID communication<br />

inverter ID<br />

0~250 1 O 11-3 O O O O O<br />

built-in<br />

0 ModBus RTU 0:<br />

02 0h1702 Int485 Proto communication<br />

protocol<br />

1<br />

2<br />

--Reserved --<br />

Serial Debug<br />

ModBus<br />

RTU<br />

O 11-3 O O O O O<br />

0 1200 bps<br />

03 0h1703 Int485 BaudR<br />

built-in<br />

communication<br />

speed<br />

1<br />

2<br />

3<br />

4<br />

2400 bps<br />

4800 bps<br />

9600 bps<br />

19200 bps<br />

3:<br />

9600 bps<br />

O 11-3 O O O O O<br />

5 38400 bps<br />

04 0h1704 Int485 Mode<br />

built-in<br />

communication<br />

frame setting<br />

0<br />

1<br />

2<br />

3<br />

D8/PN/S1<br />

D8/PN/S2<br />

D8/PE/S1<br />

D8/PO/S1<br />

0:<br />

D8/PN/S1<br />

11-3 O O O O O<br />

05 0h1705 Resp Delay<br />

Transmission delay<br />

0~1000[ms]<br />

after reception<br />

5ms O 11-3 O O O O O<br />

06<br />

Note27) - FBus S/W Ver<br />

communication<br />

option S/W version<br />

- 0.00 O Option O O O O O<br />

07 0h171B FBus ID<br />

communication<br />

option inverter ID<br />

0~255 1 O Option O O O O O<br />

08 0h1711 FBUS<br />

BaudRate<br />

FBus<br />

communication<br />

speed<br />

- 12Mbps Option O O O O O<br />

09 0h171C FieldBus LED<br />

communication<br />

option LED status<br />

- - O Option O O O O O<br />

30 0h171E ParaStatus Num 0~8 3 O 11-7 O O O O O<br />

31 0h171F Para Stauts-1 output address 1 0000~FFFF Hex 000A O 11-7 O O O O O<br />

32 0h1720 Para Stauts-2 output address 2 0000~FFFF Hex 000E O 11-7 O O O O O<br />

33 0h1721 Para Stauts-3 output address 3 0000~FFFF Hex 000F O 11-7 O O O O O<br />

34 0h1722 Para Stauts-4 output address 4 0000~FFFF Hex 0000 O 11-7 O O O O O<br />

35 0h1723 Para Stauts-5 output address 5 0000~FFFF Hex 0000 O 11-7 O O O O O<br />

36 0h1724 Para Stauts-6 output address 6 0000~FFFF Hex 0000 O 11-7 O O O O O<br />

37 0h1725 Para Stauts-7 output address 7 0000~FFFF Hex 0000 O 11-7 O O O O O<br />

38 0h1726 Para Stauts-8 output address 8 0000~FFFF Hex 0000 O 11-7 O O O O O<br />

* The grey code refers to hidden code, emerging only in case of setting of the code.<br />

Note 27) COM 06~17 codes are displayed only when the communication option card is mounted.<br />

Refer to Option manual for Option.<br />

S<br />

L<br />

V<br />

C<br />

S<br />

L<br />

T<br />

13-24<br />

V<br />

C<br />

T