Chapter 10 Protective Functions<br />

10-1<br />

10.1 Protective Functions<br />

The protective functions provided by the <strong>SV</strong>-<strong>iS7</strong> series are broadly divided into two types. One is for overheat and<br />

damage and the other is for protecting the inverter itself and preventing malfunction.<br />

10.1.1 Motor protection<br />

1) Electronic thermal (Preventing motor overheat)<br />

The electronic thermal function is automatically predicting temperature rises using the inverter output current without<br />

a temperature sensor and providing protection suited to the inverse time thermal characteristic of the motor.<br />

Group Code No. Function Display Setting Display Setting Range Unit<br />

PRT<br />

40 ETH Trip Sel 0 Yes No/Yes -<br />

41 Motor Cooling 0 Self-cool - -<br />

42 ETH 1min - 150 120~200 %<br />

43 ETH Cont - 120 50~180 %<br />

PRT-40 ETH Trip Sel : You can select the inverter operation in case of electronic thermal protective operation. On the<br />

keypad, the failure status is displayed as E-Thermal.<br />

0 : None<br />

The electronic thermal function is not active.<br />

1 : Free-Run (Free Run)<br />

The inverter output is blocked and the motor does free run.<br />

2 : Dec (Deceleration)<br />

Stop after deceleration.<br />

PRT-41 Motor Cooling : selects the operating method of the cooling fan mounted on the motor.<br />

0 : Self-cool<br />

The cooling fan connected to the motor axis, the cooling effect varies according to the rotation speed. Most general<br />

induction motors have such a structure.<br />

1 : Forced-cool<br />

This structure supplies separate power to the cooling fan. This applies to the load that should operate for a long time<br />

at a low speed and the motor exclusively for the inverter has such a structure.<br />

PRT-42 ETH 1min : inputs the amount of current that can flow continuously for a minute on the basis of the rated<br />

current (BAS-13) of the motor.