2) Code shift (function Items) in other modes and groups<br />

Chapter 6 How to Use Keypad<br />

Using Up and Down keys: The following figures give an example of shifting the code by using Up and Down keys in<br />

DRV and BAS of Parameter Mode. Code shift in other modes are the same.<br />

MON T/K N STP 0.00Hz<br />

PAR DRV N STP 0.00Hz<br />

00<br />

00<br />

Jump<br />

Jump<br />

Code<br />

Code<br />

9 CODE<br />

01 Cmd Frequency 1<br />

0.00 Hz<br />

02 Acc Time<br />

20.0 sec<br />

PAR DRV N STP 0.00Hz<br />

00 Jump Code<br />

9 CODE<br />

01 Cmd Frequency<br />

01 Cmd Frequency 0.00 Hz<br />

0.00 Hz<br />

02 Acc Time<br />

20.0 sec<br />

PAR BAS N STP 0.00Hz<br />

00 Jump Code<br />

20 CODE<br />

01 Aux Ref Src<br />

None<br />

04 Cmd 2nd Src<br />

Fx/Rx-1<br />

3) How to Shift in Jump Code<br />

- Power on, the display emerges as on the left. The present mode is Monitor<br />

Mode(MON).<br />

- Press Mode key once.<br />

- The display shows DRV of Parameter Mode. If DRV is not displayed, press Mode<br />

key until DRV emerges or press ESC once.<br />

- If you press Down key, you will shift to code No. 0 in DRV of Parameter Mode as<br />

shown on the left.<br />

- Press Right key once.<br />

- You shift to BAS of Parameter Mode.<br />

- You can shift the code by using Up or Down key.<br />

In groups of Parameter Mode and <strong>User</strong>/Macro Mode, there is Jump Code Entry item for shift to the code of each<br />

group. If the code number is high, you can shift faster than by using Up and Down keys. The following figures give an<br />

example of shift to code number 09 of DRV.<br />

PAR DRV N STP 0.00Hz<br />

00 Jump Code<br />

9 CODE<br />

01 Cmd Frequency<br />

01 Cmd Frequency 0.00 Hz<br />

0.00 Hz<br />

02 Acc Time<br />

20.0 sec<br />

PAR DRV N STP 0.00Hz<br />

00 Jump Code<br />

9 CODE<br />

01 Cmd Frequency<br />

0.00 Hz<br />

02 Acc Time<br />

20.0 sec<br />

- Check that code number 00 is displayed in the initial display of DRV of<br />

PAR(Parameter Mode).<br />

- Press Program key(PROG).<br />

- The cursor flashes so that you can enter the code number as on the left.<br />

6-13