8.1.28 Parameter initialization<br />

Chapter 8 Applied Functions<br />

Group Code No. Function Display Initial Setting Display Unit<br />

CNF 40 Parameter Init 0 No -<br />

The parameter changed by the user can be initialized to the default value set at the time of delivery. This function<br />

can initialize the data of all groups or selected groups.<br />

Initialization is not available in case of a trip or during inverter operation.<br />

1 : All Groups<br />

All the data are initialized. If you select No. 1 All Groups and press PROG, initialization starts and when initialization<br />

finishes, No. 0 No is displayed.<br />

2 : DRV ~ 13 : M2<br />

Initialization of each individual group is available. If you select the desired group and press PROG, , initialization starts<br />

and when initialization finishes, No. 0 No is displayed.<br />

8.1.29 Parameter view lock and Key lock<br />

1) Parameter Mode View Lock<br />

Group Code No. Function Display Setting Display Unit<br />

CNF<br />

50<br />

51<br />

View Lock Set<br />

View Lock PW<br />

-<br />

-<br />

Unlocked<br />

Password<br />

-<br />

-<br />

The user can set the PAR mode so that it is not viewed using a password on the keypad. In this case, all<br />

modes(CNF mode, user mode, macro mode, trip mode) but the parameter mode(PAR) are always viewed.<br />

CNF-51 View Lock PW : Registers the password to use for parameter mode view lock. For setting, see the<br />

following procedure.<br />

Procedure Description<br />

- If you press PROG key in CNF-51 code, the previous password registration display is<br />

viewed. The default value is 0. When you register for the first time, enter 0.<br />

- If there is a previous password, register it.<br />

1<br />

- If the entered password is the same as the previous password, a display emerges in<br />

which you can register a new password.<br />

- If the entered password is different from the previous password, the previous password<br />

registration display continues to viewed.<br />

2 - Register a new password.<br />

3 - When registration is completed, CNF-51 View Lock PW is displayed again.<br />

CNF-50 View Lock Set : If you enter the registered password with the view lock unlocked, “Locked” is displayed<br />

and the parameter group is not to be viewed on the keypad. If you enter the password again, “Unlocked” is viewed<br />