Chapter 8 Applied Functions<br />

2) How to Delete Individual Parameters Registered in <strong>User</strong> Group (USR Grp)<br />

Procedure Description<br />

8-48<br />

If you select 4.<strong>User</strong>Grp SelKey with the Multi-Key in CNF Mode Code<br />

1<br />

42, will be seen at the top of the display.<br />

Move the cursor to the code you want to delete in U&M Mode USR<br />

2<br />

Group.<br />

3 Press MULTI Key.<br />

4 You are asked whether to delete.<br />

5 Press YES and then PROG/ENT Key.<br />

6 Deletion is completed.<br />

CNF-25 <strong>User</strong>Grp AllDel : If you select No. 1 Yes, all the parameters registered in the user group are deleted.<br />

8.1.31 Addition to Macro Group<br />

Group Code No. Function Display Initial Setting Display Unit<br />

CNF 43 Macro Select 0 None -<br />

If you select the application load, the related function is displayed so that the inverter selects it and it can be<br />

changed in the macro group.<br />

CNF-43 Macro Select : This is the function that enables you to easily set by combining various application<br />

functions. MC1(DRAW function) or MC2(traverse function) group is displayed at <strong>User</strong> & Macro(U&M) on two<br />

functions DRAW and traverse functions<br />

This function is provided by the inverter. The user cannot add or delete the function items included in the macro but<br />

data can be changed in the macro group.<br />

Please refer to 8.1.37 Traverse operation function for trip bus.<br />

Draw function is one of open loop tension controls to maintain tension of materials stuck, using speed difference of<br />

motor which is operating by ration for main commands<br />

For more details, please refer to chapter, 8.1.1, Override frequency setting using auxiliary frequency command<br />

8.1.32 Easy start<br />

Group Code No. Function Display Initial Setting Display Unit<br />

CNF 61 Easy Start On 1 Yes -<br />

CNF-61 Easy Start On : If you set this code at Yes, ‘All’ is selected in CNF-40 Parameter Init for all the parameters<br />

of the inverter to be initialized and Easy Start is launched when power is Off/On first.