128/316 Bosch <strong>Rexroth</strong> AG | <strong>Tightening</strong> Technology 7 Data Services7.3 3964R communication7.3.3 Results output with the 3964R and RK512 protocolsSeveral tightening results outputs (data services) can be active at the same time in the CS351 Compact<strong>System</strong>. Activation takes place via the operating system.NoteEach data service requires time to calculate and thus lengthens the duration of the tightening cycle. Thisis why it makes sense to only activate the necessary data services to avoid delays.7.3.3.1 Configuring the RS232 connection to the partner controllerThe configuration of the necessary parameters takes place via the configuration of the interface.To configure the serial interface:1. In the BS<strong>350</strong> operating system, click on <strong>System</strong> → <strong>Tightening</strong> channel configuration.2. Double click on the line CS to view the interfaces.3. Double click on the lines X3C1, B1 or B2 to open the associated parameters dialog.Figure 7–31:Configuration of the interfaces<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008