11.07.2015 Views

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8 Basic Commissioning <strong>Tightening</strong> Technology | Bosch <strong>Rexroth</strong> AG 187/3168.5 Operating the Compact <strong>System</strong>IMdevFigure 8–11:Parameter dialog IMdevEnter the Serial number to monitor this interface module (optional).You can make the following settings in the Set Devicenet interface field:– MAC ID: Media Access Code Identifier, address range 0 to 63.– Baud rate: 125, 250, 500 kbit/s and auto detection.– Number of I points: Number of input control signals to be processed via the interface. Value range:16 to 64 input signal pairs.– Number of O points: Number of output control signals to be processed via the interface. Valuerange: 16 to 64 output signal pairs.– Receive data: Memory location for receiving the ID code, 0 to 64 bytes.– Send data: This field is inactive, as no data can be sent with the IMdev interface module.The grayed out fields cannot be edited. The parameters in the Configured ranges field depend on theselected number of I/O points.After all the parameters have been set, create an EDS file with the button Create EDS file. Save the file(*.eds) and import it into the DeviceNet configurator.NoteDetailed information on data exchange via Profibus can be found under “DeviceNet communication” onpage 162.⇒Click on Accept to take over this data in the configuration for the tightening channel in the BS<strong>350</strong>.B slot interfaces (B1 and B2)These interfaces are intended for use of type B interface modules from <strong>Rexroth</strong>. These include the followinginterface modules:– IMser for connecting data collection terminals (e.g. printers, scanners)– IM24V for reading 24 V I/O signals in and out (e.g. for actuating lamps and buttons)The associated parameter dialog is opened by double clicking on the parameter field in line B1 or B2 (seeFigure 8–5).⇒In the Select interface module field (see Figure 8–12), select the desired module from the dropdownlist and set its parameters.<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!