11.07.2015 Views

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

Rexroth Tightening System 350 System Documentation - Rhino ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

166/316 Bosch <strong>Rexroth</strong> AG | <strong>Tightening</strong> Technology 7 Data Services7.6 DeviceNet communicationExampleTRT-Stück T-piece T-piece120m T-Stück T-piece40m T-StückT-pieceTR4m2m3m5m 4m4m1m2m4mVerteiler Distributor,4-fach 4x3m3m2m3m2m1m3mDistributor, Verteiler8x8-fachFigure 7–58:Example of a DeviceNet network with stub lines of different lengthsThe longest line length of the DeviceNet in Fig 7–58 is 174 m; the total of all the stub lines is 42 m. Thispermits a data rate of 250 kbit/s.7.6.1.6 Power supply in DeviceNetDeviceNet permits a supply of 24 V direct current for network participants via a wire pair. This power cancome from one or more power sources.Multiple power sources are necessary if all the connected DeviceNet participants require more powerthan any single power source in the given network topology is able to supply. In this case, the plus wire(V+, red) must be stripped so that each network branch is only supplied by a single power source.The IMdev interface module does not require power from the DeviceNet for proper function. The powerstatus of V+, V– is, however, monitored.7.6.1.7 Grounding concept in DeviceNetTo ensure a constant ground potential in the entire DeviceNet and avoid ground loops, the DeviceNetmay be and must be grounded at exactly one position. Grounding is comprised of:– the V– wire and the shield wire with a 5-pin round cableor– the V– wire with a 4-wire flat cableGrounding should be done as close as possible to the physical center of the DeviceNet, preferably at apower source.NotePlease note that even in the case of multiple power sources in the DeviceNet, grounding may only be doneat a single position. The V– wire, unlike the V+ wire, may not be stripped.7.6.2 Configuration and commissioning of the DeviceNet connection7.6.2.1 Configuration of the DeviceNet connectionThe configuration of the necessary parameters and activation of communication with DeviceNet takesplace via the configuration of the interface. This is done for an IMdev interface module in the BS<strong>350</strong> operatingsystem.<strong>System</strong> <strong>350</strong> | 3 608 878 040/05.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!